Rapid X-ray energy switching for optimised K-edge subtraction imaging at narrow-band inverse Compton X-ray sources

K-edge subtraction (KES) imaging provides material-specific information exploiting the steep increase in attenuation at an absorption edge. Classically, two monochromatic images acquired with energies right above and below the K-edge are subtracted weighting one image with the approximate energy scaling of the photoelectric effect. This technique was transferred to quasi-monochromatic inverse Compton X-ray sources by implementing a filter made of the investigated material itself, yet at the cost of a reduced contrast-to-noise ratio. While switching between two spectra with a larger energy separation overcomes this issue, the X-ray energy must be changed on the timescale of seconds for this to be used in practical applications. To this end, a framework for rapid X-ray energy switching of inverse Compton X-ray sources is developed and experimentally realised. In case of a larger energy separation, the Compton contribution to the attenuation leads to artifacts using classical KES as it decreases the effective energy scaling. A theoretical model for calculating the reduced scaling factor is derived to overcome this issue. Image improvement by this optimised KES approach is experimentally demonstrated.

Authors

Publication Details

Journal
Optics Express
Published
2025-09-16
DOI
https://doi.org/10.1364/oe.571579
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid X-ray energy switching for optimised K-edge subtraction imaging at narrow-band inverse Compton X-ray sources

Martin Dierolf, Franz Pfeiffer, Klaus Achterhold, Ivan Kokhanovskyi et al.
Optics Express
Medical Imaging Techniques and Applications
article

Rapid X-ray energy switching for optimised K-edge subtraction imaging at narrow-band inverse Compton X-ray sources

Martin Dierolf, Franz Pfeiffer, Klaus Achterhold, Ivan Kokhanovskyi, Benedikt Günther
article en

Abstract

K-edge subtraction (KES) imaging provides material-specific information exploiting the steep increase in attenuation at an absorption edge. Classically, two monochromatic images acquired with energies right above and below the K-edge are subtracted weighting one image with the approximate energy scaling of the photoelectric effect. This technique was transferred to quasi-monochromatic inverse Compton X-ray sources by implementing a filter made of the investigated material itself, yet at the cost of a reduced contrast-to-noise ratio. While switching between two spectra with a larger energy separation overcomes this issue, the X-ray energy must be changed on the timescale of seconds for this to be used in practical applications. To this end, a framework for rapid X-ray energy switching of inverse Compton X-ray sources is developed and experimentally realised. In case of a larger energy separation, the Compton contribution to the attenuation leads to artifacts using classical KES as it decreases the effective energy scaling. A theoretical model for calculating the reduced scaling factor is derived to overcome this issue. Image improvement by this optimised KES approach is experimentally demonstrated.

Optics ExpressVol. 33(22)
Openalex Percentile: Top 63%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.