Assessment of Peripheral Photon Beam Skin Dose using MTS-7 TL Crystal for 15 MV Elekta Medical Linac

High energy linear accelerators are being used for treatment of cancer patients. In radiotherapy, the peripheral doses also attack the normal and healthy cells. According to the suggestion of LNT model, the issue of peripheral dose cannot be neglected. This study investigated the outfield photon beam skin dose in radiotherapy of Elekta medical Linac operated at 15 MV operational voltage using MTS-7 TL crystal. Before Linac exposure, TLDs were calibrated using 137Cs source. Then, TLDs were inserted on the phantom surface for Linac exposure. This study found that the photon skin dose increases with the increase of delivered dose and field size. As a function of the delivered dose, the highest doses were found 181.65 mSv and 78.39 mSv for delivered dose 300 cGy with field size 10 × 10 cm2 for Linac-1 and Linac-2 respectively. While, investigating the field dependency, the highest dose was found 511.30 mSv for field size 20 × 20 cm2 for 200 cGy delivered dose (Linac-1). According to the LNT model, this undesired radiation exposure may arise the risk of second cancer which makes this study extremely mandatory. Bangladesh Journal of Physics, Vol. 32, Issue 1, pp. 13 – 19, June 2025

Authors

Institutions

Publication Details

Journal
Bangladesh Journal of Physics
Published
2025-09-16
DOI
https://doi.org/10.3329/bjphy.v32i1.83754
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of Peripheral Photon Beam Skin Dose using MTS-7 TL Crystal for 15 MV Elekta Medical Linac

Mst. Ummey Habiba Musfika, Khaled Mahbub Morshed, Nourin Arobi, Santunu Purohit et al.
Bangladesh Journal of Physics
Radiation Detection and Scintillator Technologies
article

Assessment of Peripheral Photon Beam Skin Dose using MTS-7 TL Crystal for 15 MV Elekta Medical Linac

Mst. Ummey Habiba Musfika, Khaled Mahbub Morshed, Nourin Arobi, Santunu Purohit, M. Meaze, Hossen Mohammad Jamil, Md Shakilur Rahman
article en

Abstract

High energy linear accelerators are being used for treatment of cancer patients. In radiotherapy, the peripheral doses also attack the normal and healthy cells. According to the suggestion of LNT model, the issue of peripheral dose cannot be neglected. This study investigated the outfield photon beam skin dose in radiotherapy of Elekta medical Linac operated at 15 MV operational voltage using MTS-7 TL crystal. Before Linac exposure, TLDs were calibrated using 137Cs source. Then, TLDs were inserted on the phantom surface for Linac exposure. This study found that the photon skin dose increases with the increase of delivered dose and field size. As a function of the delivered dose, the highest doses were found 181.65 mSv and 78.39 mSv for delivered dose 300 cGy with field size 10 × 10 cm2 for Linac-1 and Linac-2 respectively. While, investigating the field dependency, the highest dose was found 511.30 mSv for field size 20 × 20 cm2 for 200 cGy delivered dose (Linac-1). According to the LNT model, this undesired radiation exposure may arise the risk of second cancer which makes this study extremely mandatory. Bangladesh Journal of Physics, Vol. 32, Issue 1, pp. 13 – 19, June 2025

Bangladesh Journal of PhysicsVol. 32(1)
Asian University for Women (BD), Jahangirnagar University (BD), University of Chittagong (BD), Bangladesh Atomic Energy Commission (BD)
Openalex Percentile: Top 68%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.