Local thermal resistance measurement device for fouling detection

Abstract Heat exchanger (HX) fouling is one of the main reason for heat recovery loss of efficiency and fouling detection can help to schedule maintenance operation and to optimize resource consumption. This works presents a patented Fouling Detection Probe (FDP) based on the measurement of the related induced thermal resistance thanks to an electrically heated resistance temperature device. The main features of the device are presented, as well as the measurement protocol. A 1D device model is proposed to handle the corresponding use conditions and limitations. An example of a fouling situation from the food industry is described and the related potential FDP use is discussed. The thermal resistances (convection and fouling) measured with the FDP are consistent with both the 1D-model prediction and the literature data which is the first validation step of the FDP concept. Future works will then focus on a 2D-model development to take into account the 2D heat flux and the related experimental validation with well-known fluids.

Authors

Institutions

Publication Details

Journal
Heat and Mass Transfer
Published
2025-09-16
DOI
https://doi.org/10.1007/s00231-025-03605-0
Primary Topic
Non-Destructive Testing Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Local thermal resistance measurement device for fouling detection

Zoé Anxionnaz‐Minvielle, Q. Tuan Pham, Frédéric Ducros
Heat and Mass Transfer
Non-Destructive Testing Techniques
article

Local thermal resistance measurement device for fouling detection

Zoé Anxionnaz‐Minvielle, Q. Tuan Pham, Frédéric Ducros
article en

Abstract

Abstract Heat exchanger (HX) fouling is one of the main reason for heat recovery loss of efficiency and fouling detection can help to schedule maintenance operation and to optimize resource consumption. This works presents a patented Fouling Detection Probe (FDP) based on the measurement of the related induced thermal resistance thanks to an electrically heated resistance temperature device. The main features of the device are presented, as well as the measurement protocol. A 1D device model is proposed to handle the corresponding use conditions and limitations. An example of a fouling situation from the food industry is described and the related potential FDP use is discussed. The thermal resistances (convection and fouling) measured with the FDP are consistent with both the 1D-model prediction and the literature data which is the first validation step of the FDP concept. Future works will then focus on a 2D-model development to take into account the 2D heat flux and the related experimental validation with well-known fluids.

Heat and Mass TransferVol. 61(10)
Commissariat à l'Énergie Atomique et aux Énergies Alternatives (FR), Laboratoire d’Innovation pour les Technologies des Énergies Nouvelles et les nanomatériaux (FR), Université Grenoble Alpes (FR)
Openalex Percentile: Top 74%
Non-Destructive Testing Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.