Microneedle-assisted interstitial fluid extraction combined with a 2D tellurene-based glucose sensor for personal diabetes management

The objective of this work is to develop a selective glucose sensor for real-time <i>in vivo</i> monitoring of interstitial fluid (ISF) glucose levels, addressing challenges of interference from other biomolecules. A microneedle (MN) patch was employed for ISF extraction, while a 2D tellurene (Te)-based glucose oxidase (GOX) GOX/Te/carbon cloth (CC) electrode served as the sensing element for electrochemical measurements. The sensor exhibited a low detection limit (LOD) of 0.357 μM, and a sensitivity of 0.10378 mA μM<sup>-1</sup> cm<sup>-2</sup>. <i>In vivo</i> studies in an animal model demonstrated an average glucose concentration of 5.05 mM with a rapid response time of ∼95 s. Importantly, the electrochemical measurements showed a strong correlation with commercial glucometer readings, confirming accuracy and reliability. This study highlights the potential of the proposed sensor for real-time <i>in vivo</i> glucose monitoring, paving the way for future home care diabetes management devices.

Authors

Institutions

Publication Details

Journal
Journal of Materials Chemistry B
Published
2025-01-01
DOI
https://doi.org/10.1039/d5tb00804b
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microneedle-assisted interstitial fluid extraction combined with a 2D tellurene-based glucose sensor for personal diabetes management

Parikshit Sahatiya, Venkata Vamsi Krishna Venuganti, Shreya Shashank Chauhan, Isha Basumatary
Journal of Materials Chemistry B
Spectroscopy Techniques in Biomedical and Chemical Research
article

Microneedle-assisted interstitial fluid extraction combined with a 2D tellurene-based glucose sensor for personal diabetes management

Parikshit Sahatiya, Venkata Vamsi Krishna Venuganti, Shreya Shashank Chauhan, Isha Basumatary
article en

Abstract

The objective of this work is to develop a selective glucose sensor for real-time <i>in vivo</i> monitoring of interstitial fluid (ISF) glucose levels, addressing challenges of interference from other biomolecules. A microneedle (MN) patch was employed for ISF extraction, while a 2D tellurene (Te)-based glucose oxidase (GOX) GOX/Te/carbon cloth (CC) electrode served as the sensing element for electrochemical measurements. The sensor exhibited a low detection limit (LOD) of 0.357 μM, and a sensitivity of 0.10378 mA μM<sup>-1</sup> cm<sup>-2</sup>. <i>In vivo</i> studies in an animal model demonstrated an average glucose concentration of 5.05 mM with a rapid response time of ∼95 s. Importantly, the electrochemical measurements showed a strong correlation with commercial glucometer readings, confirming accuracy and reliability. This study highlights the potential of the proposed sensor for real-time <i>in vivo</i> glucose monitoring, paving the way for future home care diabetes management devices.

Journal of Materials Chemistry BVol. 13(39)
Birla Institute of Technology and Science - Hyderabad Campus (IN)
Openalex Percentile: Top 82%
Spectroscopy Techniques in Biomedical and Chemical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Microneedle-assisted interstitial fluid extraction combined with a 2D tellurene-based glucose sensor for personal diabetes management — Parikshit Sahatiya, Venkata Vamsi Krishna Venuganti, et al. · Journal of Materials Chemistry B (2025) | TGRS Research Map | TGRS