Strengthening of Reinforced Concrete Structure Using FRP and Concrete Jacketing Methods

Applying the latest building earthquake resistance codes, SNI 1726:2019 to the reinforced concrete structure of the Islamic Center Building shows several column and beam elements that required strengthening, including beam B1, column K-Bordes, and column K3. This case study research aims to determine the appropriate strengthening method, the thickness of the additional column dimensions with the concrete jacketing method, and the number of FRP layers for columns and beams. Systematic steps in the study process starting from collecting existing data, field investigation, evaluation of structures in accordance with ASCE 41-17, structural modeling with SAP2000, and data analysis. The analysis showed that Column K-Bordes was confined with a thickness of 100 mm using concrete jacketing, Column K3 was strengthened with one layer of GFRP at the plastic hinge, and Beam B1 was strengthened with two layers of GFRP at the support area. Pull-off test showed GFRP adhesion strength values to concrete of 3.80 MPa (Beam B1) and 2.50 MPa (Column K3). This approach proves the effectiveness of the combined reinforcement method in increasing the structural capacity according to the latest earthquake codes.

Authors

Institutions

Publication Details

Journal
MEDIA KOMUNIKASI TEKNIK SIPIL
Published
2025-08-08
DOI
https://doi.org/10.14710/mkts.v31i1.72695
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Strengthening of Reinforced Concrete Structure Using FRP and Concrete Jacketing Methods

Parmo Parmo, Yusrianti Yusrianti, Abdul Hakim, Bagus Wicaksono
MEDIA KOMUNIKASI TEKNIK SIPIL
Structural Behavior of Reinforced Concrete
article

Strengthening of Reinforced Concrete Structure Using FRP and Concrete Jacketing Methods

Parmo Parmo, Yusrianti Yusrianti, Abdul Hakim, Bagus Wicaksono
article en

Abstract

Applying the latest building earthquake resistance codes, SNI 1726:2019 to the reinforced concrete structure of the Islamic Center Building shows several column and beam elements that required strengthening, including beam B1, column K-Bordes, and column K3. This case study research aims to determine the appropriate strengthening method, the thickness of the additional column dimensions with the concrete jacketing method, and the number of FRP layers for columns and beams. Systematic steps in the study process starting from collecting existing data, field investigation, evaluation of structures in accordance with ASCE 41-17, structural modeling with SAP2000, and data analysis. The analysis showed that Column K-Bordes was confined with a thickness of 100 mm using concrete jacketing, Column K3 was strengthened with one layer of GFRP at the plastic hinge, and Beam B1 was strengthened with two layers of GFRP at the support area. Pull-off test showed GFRP adhesion strength values to concrete of 3.80 MPa (Beam B1) and 2.50 MPa (Column K3). This approach proves the effectiveness of the combined reinforcement method in increasing the structural capacity according to the latest earthquake codes.

MEDIA KOMUNIKASI TEKNIK SIPILVol. 31(1)
UIN Sunan Ampel Surabaya (ID)
Openalex Percentile: Top 73%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.