Effect of a Modified Preparation Design on the Marginal and Internal Fit of 3D‐Printed Onlays: A Feasibility Study

<b>Objective:</b> Bonded onlay preparations provide minimal guidance during cementation, which may compromise seating accuracy and increase marginal and internal discrepancies, potentially affecting restoration longevity. This study aims to assess whether a modified preparation (MP) design improves onlay positioning during cementation to enhance marginal and internal fit. <b>Materials and Methods:</b> The conventional preparation (CP) design was prepared on a typodont tooth, scanned, and replicated (<i>n</i> = 20). A cross-shaped groove was added to the prepared typodont tooth to create the MP design, then scanned and replicated (<i>n</i> = 20). For both groups, a restoration was designed using computer-aided design (CAD) and computer-aided manufacturing (CAM). Each onlay was three-dimensionally (3D) printed, assessed for fit, and then bonded onto the replicas. Ten specimens from each group were sectioned horizontally and 10 vertically. Absolute marginal discrepancy (AMD) and internal cement thickness (ICT) were measured on the horizontally and vertically sectioned specimens under a stereomicroscope. Data were analyzed using the Mann-Whitney <i>U</i> test (<i>α</i> = 0.05). <b>Results:</b> The MP showed a statistically significant lower mean AMD than the CP at the palatal (<i>p</i>=0.035) and buccal (<i>p</i>=0.006) sites. However, there was no statistically significant difference at the mesial site (<i>p</i>=0.193). The CP had a statistically significant lower ICT than the MP in the vertical section (<i>p</i>=0.009), but the difference in the horizontal section was not statistically significant (<i>p</i>=0.121). <b>Conclusions:</b> The MP improved AMD compared to the CP at buccal and palatal sites, but increased ICT in the vertical section. <b>Clinical Significance:</b> The MP design showed that a minor modification to the conventional bonded onlay preparation design improved AMD but increased ICT. These findings guide clinicians in selecting optimal designs to improve restoration adaptation and longevity.

Authors

Institutions

Publication Details

Journal
International Journal of Dentistry
Published
2025-01-01
DOI
https://doi.org/10.1155/ijod/7599339
Citations
1
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
1.68
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of a Modified Preparation Design on the Marginal and Internal Fit of 3D‐Printed Onlays: A Feasibility Study

Vincent Bennani, Arthi Veerasamy, Wendy‐Ann Jansen van Vuuren, Stephanie Ung
1 citations
International Journal of Dentistry
Dental materials and restorations
1.68
article

Effect of a Modified Preparation Design on the Marginal and Internal Fit of 3D‐Printed Onlays: A Feasibility Study

Vincent Bennani, Arthi Veerasamy, Wendy‐Ann Jansen van Vuuren, Stephanie Ung
article en
1 citations

Abstract

<b>Objective:</b> Bonded onlay preparations provide minimal guidance during cementation, which may compromise seating accuracy and increase marginal and internal discrepancies, potentially affecting restoration longevity. This study aims to assess whether a modified preparation (MP) design improves onlay positioning during cementation to enhance marginal and internal fit. <b>Materials and Methods:</b> The conventional preparation (CP) design was prepared on a typodont tooth, scanned, and replicated (<i>n</i> = 20). A cross-shaped groove was added to the prepared typodont tooth to create the MP design, then scanned and replicated (<i>n</i> = 20). For both groups, a restoration was designed using computer-aided design (CAD) and computer-aided manufacturing (CAM). Each onlay was three-dimensionally (3D) printed, assessed for fit, and then bonded onto the replicas. Ten specimens from each group were sectioned horizontally and 10 vertically. Absolute marginal discrepancy (AMD) and internal cement thickness (ICT) were measured on the horizontally and vertically sectioned specimens under a stereomicroscope. Data were analyzed using the Mann-Whitney <i>U</i> test (<i>α</i> = 0.05). <b>Results:</b> The MP showed a statistically significant lower mean AMD than the CP at the palatal (<i>p</i>=0.035) and buccal (<i>p</i>=0.006) sites. However, there was no statistically significant difference at the mesial site (<i>p</i>=0.193). The CP had a statistically significant lower ICT than the MP in the vertical section (<i>p</i>=0.009), but the difference in the horizontal section was not statistically significant (<i>p</i>=0.121). <b>Conclusions:</b> The MP improved AMD compared to the CP at buccal and palatal sites, but increased ICT in the vertical section. <b>Clinical Significance:</b> The MP design showed that a minor modification to the conventional bonded onlay preparation design improved AMD but increased ICT. These findings guide clinicians in selecting optimal designs to improve restoration adaptation and longevity.

International Journal of DentistryVol. 2025(1)
University of Otago (NZ)
Openalex Percentile: Top 15%
Dental materials and restorations
1.68
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.