δ(<sup>18</sup>O/<sup>16</sup>O) Determinations in Water Using Inductively Coupled Plasma–Tandem Mass Spectrometry

A fully validated measurement approach for the determination of oxygen isotope ratios in water using inductively coupled plasma-tandem mass spectrometry (ICP-MS/MS) is described for the first time. Deuterium was used as a reaction gas to mass-shift the oxygen isotopes to the OD<sub>3</sub><sup>+</sup> product ion, allowing for the removal of polyatomic ions (<sup>16</sup>O<sup>1</sup>H<sup>+</sup> and <sup>16</sup>O<sup>1</sup>H<sub>2</sub><sup>+</sup>) generated in the plasma that interfere on the less abundant oxygen stable isotopes (<sup>17</sup>O and <sup>18</sup>O). The developed methodology was validated for δ<sub>VSMOW-SLAP</sub>(<sup>18</sup>O/<sup>16</sup>O) determinations using four internationally recognized IAEA reference materials, as well as 11 in-house laboratory isotope reference materials that were characterized by isotope ratio mass spectrometry and cavity ring-down spectroscopy. δ<sub>VSMOW-SLAP</sub>(<sup>18</sup>O/<sup>16</sup>O) values determined by ICP-MS/MS and the reference methods overlapped within the uncertainties and showed no significant difference for water materials with a low matrix load. Elevated levels of sodium, chloride, and silicon in the matrix lead to isotope ratio shifts of up to 12‰ in both the positive and negative directions. Additionally, comparisons with indicative values from the reference materials demonstrated that δ<sub>VSMOW-SLAP</sub>(<sup>17</sup>O/<sup>16</sup>O) determinations are also possible using the ICP-MS/MS approach. While the uncertainty of the developed approach (median uncertainty <i>u</i><sub>c</sub>(δ<sub>VSMOW-SLAP</sub>(<sup>18</sup>O/<sup>16</sup>O)) = 0.70‰) is not currently able to match that of existing methodologies, it is envisioned that oxygen isotope ratio determinations can be performed alongside multielemental analysis by a wider community for applications where lower uncertainties are not required.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-09-16
DOI
https://doi.org/10.1021/acs.analchem.5c02607
Citations
3
Primary Topic
Groundwater and Isotope Geochemistry
Type
article
Field-Weighted Citation Impact
4.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

δ(18O/16O) Determinations in Water Using Inductively Coupled Plasma–Tandem Mass Spectrometry

Federica Camin, Maria Hoerhold, Johanna Irrgeher, Edward C. Conrad et al.
3 citations
Analytical Chemistry
Groundwater and Isotope Geochemistry
4.01
article

δ(18O/16O) Determinations in Water Using Inductively Coupled Plasma–Tandem Mass Spectrometry

Federica Camin, Maria Hoerhold, Johanna Irrgeher, Edward C. Conrad, Rémi Dallmayr, Polona Vreča, Shaun T. Lancaster, Klara Žagar, Thomas Prohaska, Pascal Bohleber, Melanie Behrens
article en
3 citations

Abstract

A fully validated measurement approach for the determination of oxygen isotope ratios in water using inductively coupled plasma-tandem mass spectrometry (ICP-MS/MS) is described for the first time. Deuterium was used as a reaction gas to mass-shift the oxygen isotopes to the OD<sub>3</sub><sup>+</sup> product ion, allowing for the removal of polyatomic ions (<sup>16</sup>O<sup>1</sup>H<sup>+</sup> and <sup>16</sup>O<sup>1</sup>H<sub>2</sub><sup>+</sup>) generated in the plasma that interfere on the less abundant oxygen stable isotopes (<sup>17</sup>O and <sup>18</sup>O). The developed methodology was validated for δ<sub>VSMOW-SLAP</sub>(<sup>18</sup>O/<sup>16</sup>O) determinations using four internationally recognized IAEA reference materials, as well as 11 in-house laboratory isotope reference materials that were characterized by isotope ratio mass spectrometry and cavity ring-down spectroscopy. δ<sub>VSMOW-SLAP</sub>(<sup>18</sup>O/<sup>16</sup>O) values determined by ICP-MS/MS and the reference methods overlapped within the uncertainties and showed no significant difference for water materials with a low matrix load. Elevated levels of sodium, chloride, and silicon in the matrix lead to isotope ratio shifts of up to 12‰ in both the positive and negative directions. Additionally, comparisons with indicative values from the reference materials demonstrated that δ<sub>VSMOW-SLAP</sub>(<sup>17</sup>O/<sup>16</sup>O) determinations are also possible using the ICP-MS/MS approach. While the uncertainty of the developed approach (median uncertainty <i>u</i><sub>c</sub>(δ<sub>VSMOW-SLAP</sub>(<sup>18</sup>O/<sup>16</sup>O)) = 0.70‰) is not currently able to match that of existing methodologies, it is envisioned that oxygen isotope ratio determinations can be performed alongside multielemental analysis by a wider community for applications where lower uncertainties are not required.

Analytical ChemistryVol. 97(38)
Alfred-Wegener-Institut Helmholtz-Zentrum für Polar- und Meeresforschung (DE), International Atomic Energy Agency (AT), University of Calgary (CA), Montanuniversität Leoben (AT), Analytical Services (US), Jožef Stefan Institute (SI), Analytical Engineering (United States) (US)
Openalex Percentile: Top 7%
Groundwater and Isotope Geochemistry
4.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.