Comparison of Bone Density and Crestal Bone Loss Between Immediately Temporized and Submerged Implants in the Posterior Mandible: A Radiovisiographic Study

<b>Purpose:</b> This study aimed to evaluate and compare alveolar bone density and crestal bone loss (CBL) around immediately temporized implants (ITIs) and conventionally placed submerged implants (CIs) in the posterior mandible using radiovisiography (RVG). <b>Methods:</b> In this prospective, randomized, split-mouth clinical study, nine patients with bilateral posterior mandibular edentulism were enrolled. A bone-level implant was placed bilaterally in each patient. One side received an immediate temporized, while the contralateral side received a CI. Standardized RVGs were obtained at baseline, 3 months, and 6 months. Alveolar bone density and CBL were measured using ImageJ software. Data were analyzed using paired <i>t</i>-tests with significance set at <i>p</i> < 0.05. <b>Results:</b> No statistically significant differences in alveolar bone density or CBL were observed between the ITI and conventional groups at any follow-up interval. Mean alveolar bone densities were higher in the ITI group at all intervals (baseline: 136.22 ± 36.23, 3 months: 137.03 ± 34, 6 months: 136.28 ± 34.59) compared to the conventional group (baseline: 136.56 ± 24.26, 3 months: 126.53 ± 34.93, 6 months: 119.95 ± 43.35). At 3 months, the ITI group exhibited greater CBL (0.22 ± 0.63 mm) than the conventional group (0.15 ± 0.83 mm). However, at 6 months, the ITI implants exhibited less CBL (- 0.07 ± 0.47 mm) compared to the conventional implants (0.19 ± 0.78 mm). <b>Conclusion:</b> Immediate temporization under nonfunctional loading did not negatively affect peri-implant bone compared to conventional submerged healing. These results support its clinical use in appropriately selected cases.

Authors

Institutions

Publication Details

Journal
International Journal of Dentistry
Published
2025-01-01
DOI
https://doi.org/10.1155/ijod/2797748
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Bone Density and Crestal Bone Loss Between Immediately Temporized and Submerged Implants in the Posterior Mandible: A Radiovisiographic Study

Prashant Bajantri, Vignesh Kamath, Gautami Pal, Shobha Rodrigues et al.
International Journal of Dentistry
Dental Implant Techniques and Outcomes
article

Comparison of Bone Density and Crestal Bone Loss Between Immediately Temporized and Submerged Implants in the Posterior Mandible: A Radiovisiographic Study

Prashant Bajantri, Vignesh Kamath, Gautami Pal, Shobha Rodrigues, Arvind Ramanathan, Umesh Pai, Thilak Shetty, Mahesh Mundathaje, Srikant Natarajan, Sandipan Mukherjee, Sharon Saldanha, Sanchit Bansal, Ann Sales
article en

Abstract

<b>Purpose:</b> This study aimed to evaluate and compare alveolar bone density and crestal bone loss (CBL) around immediately temporized implants (ITIs) and conventionally placed submerged implants (CIs) in the posterior mandible using radiovisiography (RVG). <b>Methods:</b> In this prospective, randomized, split-mouth clinical study, nine patients with bilateral posterior mandibular edentulism were enrolled. A bone-level implant was placed bilaterally in each patient. One side received an immediate temporized, while the contralateral side received a CI. Standardized RVGs were obtained at baseline, 3 months, and 6 months. Alveolar bone density and CBL were measured using ImageJ software. Data were analyzed using paired <i>t</i>-tests with significance set at <i>p</i> < 0.05. <b>Results:</b> No statistically significant differences in alveolar bone density or CBL were observed between the ITI and conventional groups at any follow-up interval. Mean alveolar bone densities were higher in the ITI group at all intervals (baseline: 136.22 ± 36.23, 3 months: 137.03 ± 34, 6 months: 136.28 ± 34.59) compared to the conventional group (baseline: 136.56 ± 24.26, 3 months: 126.53 ± 34.93, 6 months: 119.95 ± 43.35). At 3 months, the ITI group exhibited greater CBL (0.22 ± 0.63 mm) than the conventional group (0.15 ± 0.83 mm). However, at 6 months, the ITI implants exhibited less CBL (- 0.07 ± 0.47 mm) compared to the conventional implants (0.19 ± 0.78 mm). <b>Conclusion:</b> Immediate temporization under nonfunctional loading did not negatively affect peri-implant bone compared to conventional submerged healing. These results support its clinical use in appropriately selected cases.

International Journal of DentistryVol. 2025(1)
Manipal Academy of Higher Education (IN), Swami Devi Dyal Hospital and Dental College (IN)
Openalex Percentile: Top 65%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.