Biomechanical Analysis of Fixation Strength in Unstable Intertrochanteric Femoral Fracture Models Based on the Caput–Collum–Diaphyseal Angle of Cephalomedullary Nails and Position of Lag Screws

<b>Background/Objectives:</b> The combined effect of femoral neck-shaft angle and lag screw position on unstable intertrochanteric fracture fixation has not been well established. This biomechanical study evaluated the effects of two caput-collum-diaphyseal (CCD) angles and two lag screw positions on construct stability. <b>Methods:</b> Twenty-four synthetic femurs with identical AO/OTA 31-A2.2 fracture gaps (2 mm) were fixed using cephalomedullary nails with CCD angles of either 125° or 130°, each with a central or inferior (calcar) lag screw (<i>n</i> = 6/group). Constructs were tested in a single-leg stance under preloading, cyclic loading (75-750 N, 10,000 cycles, and 2 Hz), and axial loading to failure. Lag screw migration was measured radiographically, and femoral head rotation was recorded using a three-dimensional coordinate-measuring device. Stiffness, failure load, and rotations were compared using the Kruskal-Wallis and Bonferroni post hoc tests. <b>Results:</b> The 125° inferior configuration showed the highest stiffness (188 ± 15 N/mm, <i>p</i> = 0.038) and failure load (1350 ± 97 N, <i>p</i> = 0.047), with the least screw migration (0.54 ± 0.11 mm, <i>p</i> = 0.003), significantly outperforming the 125° central and 130° central constructs. However, it exhibited greater varus collapse (2.25 ± 0.27°, <i>p</i> = 0.013) and axial rotation (~20-30% higher than others, <i>p</i> = 0.025). Screw position had a stronger effect on stability than the CCD angle, although the 130° inferior construct showed slightly less varus deformation. <b>Conclusions:</b> An inferior calcar-guided lag screw improves fixation strength and stiffness in unstable intertrochanteric fractures, particularly in those with a 125° nail. However, this configuration increases varus and rotational displacement, warranting adjunct measures to enhance rotational control in clinical applications.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-09-15
DOI
https://doi.org/10.3390/jcm14186495
Citations
1
Primary Topic
Hip and Femur Fractures
Type
article
Field-Weighted Citation Impact
2.01

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical Analysis of Fixation Strength in Unstable Intertrochanteric Femoral Fracture Models Based on the Caput–Collum–Diaphyseal Angle of Cephalomedullary Nails and Position of Lag Screws

Hyung Keun Song, Yong-Cheol Yoon, Sung Jae Lee
1 citations
Journal of Clinical Medicine
Hip and Femur Fractures
2.01
article

Biomechanical Analysis of Fixation Strength in Unstable Intertrochanteric Femoral Fracture Models Based on the Caput–Collum–Diaphyseal Angle of Cephalomedullary Nails and Position of Lag Screws

Hyung Keun Song, Yong-Cheol Yoon, Sung Jae Lee
article en
1 citations

Abstract

<b>Background/Objectives:</b> The combined effect of femoral neck-shaft angle and lag screw position on unstable intertrochanteric fracture fixation has not been well established. This biomechanical study evaluated the effects of two caput-collum-diaphyseal (CCD) angles and two lag screw positions on construct stability. <b>Methods:</b> Twenty-four synthetic femurs with identical AO/OTA 31-A2.2 fracture gaps (2 mm) were fixed using cephalomedullary nails with CCD angles of either 125° or 130°, each with a central or inferior (calcar) lag screw (<i>n</i> = 6/group). Constructs were tested in a single-leg stance under preloading, cyclic loading (75-750 N, 10,000 cycles, and 2 Hz), and axial loading to failure. Lag screw migration was measured radiographically, and femoral head rotation was recorded using a three-dimensional coordinate-measuring device. Stiffness, failure load, and rotations were compared using the Kruskal-Wallis and Bonferroni post hoc tests. <b>Results:</b> The 125° inferior configuration showed the highest stiffness (188 ± 15 N/mm, <i>p</i> = 0.038) and failure load (1350 ± 97 N, <i>p</i> = 0.047), with the least screw migration (0.54 ± 0.11 mm, <i>p</i> = 0.003), significantly outperforming the 125° central and 130° central constructs. However, it exhibited greater varus collapse (2.25 ± 0.27°, <i>p</i> = 0.013) and axial rotation (~20-30% higher than others, <i>p</i> = 0.025). Screw position had a stronger effect on stability than the CCD angle, although the 130° inferior construct showed slightly less varus deformation. <b>Conclusions:</b> An inferior calcar-guided lag screw improves fixation strength and stiffness in unstable intertrochanteric fractures, particularly in those with a 125° nail. However, this configuration increases varus and rotational displacement, warranting adjunct measures to enhance rotational control in clinical applications.

Journal of Clinical MedicineVol. 14(18)
Inje University (KR), Gachon University (KR), Ajou University (KR)
National Research Foundation, National Research Foundation of Korea, Ministry of Science and ICT, South Korea
Openalex Percentile: Top 12%
Hip and Femur Fractures
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.