Biomechanical Analysis of Fixation Strength in Unstable Intertrochanteric Femoral Fracture Models Based on the Caput–Collum–Diaphyseal Angle of Cephalomedullary Nails and Position of Lag Screws
<b>Background/Objectives:</b> The combined effect of femoral neck-shaft angle and lag screw position on unstable intertrochanteric fracture fixation has not been well established. This biomechanical study evaluated the effects of two caput-collum-diaphyseal (CCD) angles and two lag screw positions on construct stability. <b>Methods:</b> Twenty-four synthetic femurs with identical AO/OTA 31-A2.2 fracture gaps (2 mm) were fixed using cephalomedullary nails with CCD angles of either 125° or 130°, each with a central or inferior (calcar) lag screw (<i>n</i> = 6/group). Constructs were tested in a single-leg stance under preloading, cyclic loading (75-750 N, 10,000 cycles, and 2 Hz), and axial loading to failure. Lag screw migration was measured radiographically, and femoral head rotation was recorded using a three-dimensional coordinate-measuring device. Stiffness, failure load, and rotations were compared using the Kruskal-Wallis and Bonferroni post hoc tests. <b>Results:</b> The 125° inferior configuration showed the highest stiffness (188 ± 15 N/mm, <i>p</i> = 0.038) and failure load (1350 ± 97 N, <i>p</i> = 0.047), with the least screw migration (0.54 ± 0.11 mm, <i>p</i> = 0.003), significantly outperforming the 125° central and 130° central constructs. However, it exhibited greater varus collapse (2.25 ± 0.27°, <i>p</i> = 0.013) and axial rotation (~20-30% higher than others, <i>p</i> = 0.025). Screw position had a stronger effect on stability than the CCD angle, although the 130° inferior construct showed slightly less varus deformation. <b>Conclusions:</b> An inferior calcar-guided lag screw improves fixation strength and stiffness in unstable intertrochanteric fractures, particularly in those with a 125° nail. However, this configuration increases varus and rotational displacement, warranting adjunct measures to enhance rotational control in clinical applications.
Authors
- Hyung Keun Song (ORCID: https://orcid.org/0000-0001-5486-2560)
- Yong-Cheol Yoon (ORCID: https://orcid.org/0000-0003-4137-0764)
- Sung Jae Lee (ORCID: https://orcid.org/0000-0002-8094-3740)
Institutions
- Inje University (KR)
- Gachon University (KR)
- Ajou University (KR)
Publication Details
- Journal
- Journal of Clinical Medicine
- Published
- 2025-09-15
- DOI
- https://doi.org/10.3390/jcm14186495
- Citations
- 1
- Primary Topic
- Hip and Femur Fractures
- Type
- article
- Field-Weighted Citation Impact
- 2.01
Funders
- National Research Foundation
- National Research Foundation of Korea
- Ministry of Science and ICT, South Korea