Portable Vision Testing and Optometry Technology

We developed an innovative method using the focal length change in the zoom lens to enable subjects with refractive errors to see the E chart image. For myopes, the distant E chart image is in front of the retina. By using the focal length change in the zoom lens, the E chart is located inside the first focal point of the zoom, diverging light. The E chart image is formed on the retina, and the myopes can clearly see the E chart. For hyperopia, the distant E chart image is behind the retina. Similarly, by using the focal length change in the zoom lens, the E chart is located outside the first focal point of the zoom lens and converges light, and the E chart image is formed on the retina. Hyperopia patients can clearly see the converged E chart. The test for myopia was repeated 30 times. The average of the two test values was −0.7, and the rest were −0.8. The error in the two test datasets can be minimized by optimizing the zoom lens, reducing the optical image value, and expanding the field of view (FOV).

Authors

Institutions

Publication Details

Published
2025-09-15
DOI
https://doi.org/10.3390/engproc2025103028
Primary Topic
CCD and CMOS Imaging Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Portable Vision Testing and Optometry Technology

Der‐Chin Chen, Feng‐Ming Yeh, K.S. Chen, Wei‐Hsin Chen et al.
CCD and CMOS Imaging Sensors
article

Portable Vision Testing and Optometry Technology

Der‐Chin Chen, Feng‐Ming Yeh, K.S. Chen, Wei‐Hsin Chen, Ya‐Hui Hsieh, C.-J.G. Yeh
article en

Abstract

We developed an innovative method using the focal length change in the zoom lens to enable subjects with refractive errors to see the E chart image. For myopes, the distant E chart image is in front of the retina. By using the focal length change in the zoom lens, the E chart is located inside the first focal point of the zoom, diverging light. The E chart image is formed on the retina, and the myopes can clearly see the E chart. For hyperopia, the distant E chart image is behind the retina. Similarly, by using the focal length change in the zoom lens, the E chart is located outside the first focal point of the zoom lens and converges light, and the E chart image is formed on the retina. Hyperopia patients can clearly see the converged E chart. The test for myopia was repeated 30 times. The average of the two test values was −0.7, and the rest were −0.8. The error in the two test datasets can be minimized by optimizing the zoom lens, reducing the optical image value, and expanding the field of view (FOV).

Hsin Sheng College of Medical Care and Management (TW), Ming Chuan University (TW), Yuanpei University (TW)
Far Eastern Memorial Hospital
Openalex Percentile: Top 76%
CCD and CMOS Imaging Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Portable Vision Testing and Optometry Technology — Der‐Chin Chen, Feng‐Ming Yeh, et al. · (2025) | TGRS Research Map | TGRS