Evaluating The Validity Of Foot-foot And Hand-hand Bia Devices For Body Composition Assessment In Young Adults

PURPOSE: The purpose of this study was twofold. First, to compare percentage body fat results across the Hand-Hand BIA (HH) Foot-Foot BIA1 (FF1), and Foot-Foot BIA2 (FF2) devices. Second, identify which device provides values closest to the air displacement plethysmography (ADP) technique. METHODS: Five hundred and thirty-seven participants (317 females, age 21.2 ± 5.8 years, and 220 males age 22.6 ± 7.5 years) underwent percent body fat (%BF) assessments using four methods (ADP, HH, FF1, and FF2) in a randomized sequence to reduce bias. Pearson correlation assessed interrelationships, paired sample t-tests evaluated mean differences, and mean absolute differences (MAD) quantified individual errors. All analyses were sex specific. RESULTS: Mean ADP %BF values were 25.8 ± 7.6% for females and 14.5 ± 7.2% for males. Bias values for HH, FF1, and FF2 were -3.4%, -2.6%, and -1.4% for females, and -1.5%, -2.5%, and 1.4% for males, with all mean %BF significantly different from ADP (all p ≤ 0.001). Correlations ranged from 0.77 to 0.80 for females and 0.65 to 0.74 for males. MAD values for females changed from 4.1% to 5.0%, and for males from 4.1% to 4.6%. Significant mean differences were observed between HH and both FF devices (p ≤ 0.01). Correlations between HH and FF1, and HH and FF2, were 0.84 and 0.82 for females, and 0.74 and 0.72 for males. CONCLUSIONS: Moderate to moderately high correlations and significant mean differences were observed between ADP and BIA %BF measures. However, biases and MAD remained within the accepted margin of error for the instruments. Significant differences were also found between BIA devices, but biases and MAD were still within the acceptable range. Practical Applications: Both Foot-Foot and Hand-Hand BIA devices are valid for estimating %BF in young adults. However, it is not advisable to interchange the BIA devices when conducting pre- and post-assessment analyses.

Authors

Institutions

Publication Details

Journal
Medicine & Science in Sports & Exercise
Published
2025-09-16
DOI
https://doi.org/10.1249/01.mss.0001160944.63374.26
Primary Topic
Body Composition Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating The Validity Of Foot-foot And Hand-hand Bia Devices For Body Composition Assessment In Young Adults

JOHN G. KUHNS, Athiko Loli, Tamlyn Shields, Alexander McDaniel et al.
Medicine & Science in Sports & Exercise
Body Composition Measurement Techniques
article

Evaluating The Validity Of Foot-foot And Hand-hand Bia Devices For Body Composition Assessment In Young Adults

JOHN G. KUHNS, Athiko Loli, Tamlyn Shields, Alexander McDaniel, Juan Carlos Vélez, Michel Heijnen, Christian Barnes, Andrea Berni, Wayland Tseh, Lindsey H. Schroeder, Sergio Guillén, Sarah Noland, Jessica Van Meter, Tiago V. Barreira, Bri Moye, Jaden Koonts, Weronika Matuszewski, Summer Herbertson, Hayley Hrenyo
article en

Abstract

PURPOSE: The purpose of this study was twofold. First, to compare percentage body fat results across the Hand-Hand BIA (HH) Foot-Foot BIA1 (FF1), and Foot-Foot BIA2 (FF2) devices. Second, identify which device provides values closest to the air displacement plethysmography (ADP) technique. METHODS: Five hundred and thirty-seven participants (317 females, age 21.2 ± 5.8 years, and 220 males age 22.6 ± 7.5 years) underwent percent body fat (%BF) assessments using four methods (ADP, HH, FF1, and FF2) in a randomized sequence to reduce bias. Pearson correlation assessed interrelationships, paired sample t-tests evaluated mean differences, and mean absolute differences (MAD) quantified individual errors. All analyses were sex specific. RESULTS: Mean ADP %BF values were 25.8 ± 7.6% for females and 14.5 ± 7.2% for males. Bias values for HH, FF1, and FF2 were -3.4%, -2.6%, and -1.4% for females, and -1.5%, -2.5%, and 1.4% for males, with all mean %BF significantly different from ADP (all p ≤ 0.001). Correlations ranged from 0.77 to 0.80 for females and 0.65 to 0.74 for males. MAD values for females changed from 4.1% to 5.0%, and for males from 4.1% to 4.6%. Significant mean differences were observed between HH and both FF devices (p ≤ 0.01). Correlations between HH and FF1, and HH and FF2, were 0.84 and 0.82 for females, and 0.74 and 0.72 for males. CONCLUSIONS: Moderate to moderately high correlations and significant mean differences were observed between ADP and BIA %BF measures. However, biases and MAD remained within the accepted margin of error for the instruments. Significant differences were also found between BIA devices, but biases and MAD were still within the acceptable range. Practical Applications: Both Foot-Foot and Hand-Hand BIA devices are valid for estimating %BF in young adults. However, it is not advisable to interchange the BIA devices when conducting pre- and post-assessment analyses.

Medicine & Science in Sports & ExerciseVol. 57(10S)
University of North Carolina Wilmington (US), Syracuse University (US)
Openalex Percentile: Top 69%
Body Composition Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.