Accelerometry Harmonization Across Research-grade And Consumer Wearable Devices: A Comparison Of MIMS, ENMO And MAD

PURPOSE: Accelerometry metrics, including Euclidean Norm Minus One (ENMO), Mean Amplitude Deviation (MAD), and Monitor-Independent Movement Summary (MIMS) units, are meant to harmonize across devices with different sampling rates and dynamic ranges. Current evidence exploring the potential of these metrics to be device-agnostic has focused on ENMO and MAD and has relied on shaker table studies. The objective of this study was to identify which metric (ENMO, MAD, MIMS) best harmonizes across devices with varying sampling rates and dynamic ranges in children. METHODS: Children (n = 239; 9.3 ± 2.1 years, 47% female, 30% Black) wore Actigraph GT9X (+/- 8 g, 50 Hz) research-grade accelerometers and were randomized to wear two of three consumer wearables including Apple Watch Series 7 (+/- 16 g, 50 Hz), Garmin Vivoactive 4S (+/- 8 g, 25 Hz), and Fitbit Sense (+/- 4 g, 50 Hz) on their non-dominant wrist, while participating in 60 minutes of simulated free-living activities (i.e., walking, running, soccer). The standard deviation (SD) across z-scores for ENMO, MAD and MIMS of each device was calculated at the second level as an estimate of variability across devices. Lin’s Concordance Correlation Coefficient (CCC) was calculated for each combination of devices by metric to determine agreement. RESULTS: The SD of z-score across devices was the lowest, indicating better harmonization, for MAD (0.12 ± .23), followed by ENMO (0.24 ± .50), and then MIMS (0.26 ± .39). Lin’s CCC was strongest across all combinations of devices for MAD, with coefficients ranging from 0.89 for Apple and Fitbit to 0.96 for Apple and Actigraph. Lin’s CCC for MIMS ranged from 0.70 for Apple and Fitbit to 0.83 for Apple and Actigraph, and was lowest for ENMO, ranging from 0.62 for Garmin and Actigraph to 0.76 for Apple and Actigraph. CONCLUSIONS: MAD appears to perform best at harmonizing across research-grade and consumer devices with different sampling rates and dynamic ranges in children. Supported by: This publication was made possible in part by Grant Number T32-GM081740 and T32-GM145226 from NIH-NIGMS. Research reported in this publication was also supported in part by the National Institute of Diabetes and Digestive and Kidney Diseases Award Number R01DK129215. Co-author White was supported in part by National Institute of Diabetes and Digestive and Kidney Diseases Award Number F31DK136205. Its contents are solely the responsibility of the authors and do not necessarily represent the official views of the NIGMS or NIH.

Authors

Institutions

Publication Details

Journal
Medicine & Science in Sports & Exercise
Published
2025-09-16
DOI
https://doi.org/10.1249/01.mss.0001159820.84295.a6
Primary Topic
Additive Manufacturing and 3D Printing Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accelerometry Harmonization Across Research-grade And Consumer Wearable Devices: A Comparison Of MIMS, ENMO And MAD

Stuart J. Fairclough, R. Glenn Weaver, J. W. White, Elizabeth L. Adams et al.
Medicine & Science in Sports & Exercise
Additive Manufacturing and 3D Printing Technologies
article

Accelerometry Harmonization Across Research-grade And Consumer Wearable Devices: A Comparison Of MIMS, ENMO And MAD

Stuart J. Fairclough, R. Glenn Weaver, J. W. White, Elizabeth L. Adams, Bridget Armstrong, Olivia Finnegan, Michael W. Beets, Sarah Burkart, Srihari Nelakuditi, Rahul Ghosal, Hongpeng Yang, Zifei Zhong
article en

Abstract

PURPOSE: Accelerometry metrics, including Euclidean Norm Minus One (ENMO), Mean Amplitude Deviation (MAD), and Monitor-Independent Movement Summary (MIMS) units, are meant to harmonize across devices with different sampling rates and dynamic ranges. Current evidence exploring the potential of these metrics to be device-agnostic has focused on ENMO and MAD and has relied on shaker table studies. The objective of this study was to identify which metric (ENMO, MAD, MIMS) best harmonizes across devices with varying sampling rates and dynamic ranges in children. METHODS: Children (n = 239; 9.3 ± 2.1 years, 47% female, 30% Black) wore Actigraph GT9X (+/- 8 g, 50 Hz) research-grade accelerometers and were randomized to wear two of three consumer wearables including Apple Watch Series 7 (+/- 16 g, 50 Hz), Garmin Vivoactive 4S (+/- 8 g, 25 Hz), and Fitbit Sense (+/- 4 g, 50 Hz) on their non-dominant wrist, while participating in 60 minutes of simulated free-living activities (i.e., walking, running, soccer). The standard deviation (SD) across z-scores for ENMO, MAD and MIMS of each device was calculated at the second level as an estimate of variability across devices. Lin’s Concordance Correlation Coefficient (CCC) was calculated for each combination of devices by metric to determine agreement. RESULTS: The SD of z-score across devices was the lowest, indicating better harmonization, for MAD (0.12 ± .23), followed by ENMO (0.24 ± .50), and then MIMS (0.26 ± .39). Lin’s CCC was strongest across all combinations of devices for MAD, with coefficients ranging from 0.89 for Apple and Fitbit to 0.96 for Apple and Actigraph. Lin’s CCC for MIMS ranged from 0.70 for Apple and Fitbit to 0.83 for Apple and Actigraph, and was lowest for ENMO, ranging from 0.62 for Garmin and Actigraph to 0.76 for Apple and Actigraph. CONCLUSIONS: MAD appears to perform best at harmonizing across research-grade and consumer devices with different sampling rates and dynamic ranges in children. Supported by: This publication was made possible in part by Grant Number T32-GM081740 and T32-GM145226 from NIH-NIGMS. Research reported in this publication was also supported in part by the National Institute of Diabetes and Digestive and Kidney Diseases Award Number R01DK129215. Co-author White was supported in part by National Institute of Diabetes and Digestive and Kidney Diseases Award Number F31DK136205. Its contents are solely the responsibility of the authors and do not necessarily represent the official views of the NIGMS or NIH.

Medicine & Science in Sports & ExerciseVol. 57(10S)
University of South Carolina (US), Edge Hill University (GB)
Openalex Percentile: Top 73%
Additive Manufacturing and 3D Printing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.