Evaluation Of Garmin And Fitbit Algorithms To Automatically Detect Children's Semi-structured Activity Type And Duration

Consumer wearables with automatic activity detection algorithms have the potential to improve the assessment of children’s physical activity energy expenditure. PURPOSE: This study will evaluate the ability of Garmin Move IQ and Fitbit SmartTrack automatic activity detection algorithms to detect children’s activity type and duration compared to direct observation (DO). METHODS: Children (n = 17, 11.0 ± 1.6 years, 58.8% female) completed a ~ 60-minute, semi-structured activity protocol while wearing a Garmin Vivoactive 4S and a Fitbit Sense concurrently on their nondominant wrist. The watches were counterbalanced with each protocol, and children’s activities were measured via DO. The protocol was counterbalanced and consisted of 3 activities (walking, running [run 10 meters following the sound of an audio recording], and outdoor biking), each separated by seated rest and lasting ≥10 minutes. Activity type and duration data from Garmin and Fitbit were exported via Fitabase and translated into 1-second epochs. Epoch-by-epoch (i.e., accuracy) and measurement agreement (i.e., absolute error) analyses were conducted to evaluate the performance of Garmin Move IQ and Fitbit SmartTrack for detecting children’s activity type and duration compared to DO. RESULTS: Garmin Move IQ correctly predicted biking 71.9% (95%CI = 54.9%, 88.8%), running 5.8% (95%CI = -5.6%, 17.2%), and walking 47.6% (95%CI = 25.6%, 69.5%) of the time, while Fitbit SmartTrack correctly predicted biking 63.9% (95%CI = 43.5%, 84.3%), running 82.1% (95%CI = 67.3%, 97.0%), and walking 49.1% (95%CI = 28.9%, 69.4%) of the time. For duration, Fitbit SmartTrack produced lower mean absolute errors (biking = 3.2 ± 4.6 minutes, running = 3.7 ± 7.8, walking = 10.5 ± 13.1) than Garmin Move IQ (biking = 5.3 ± 4.6 minutes, running = 9.5 ± 2.4, walking = 16.6 ± 10.3). CONCLUSIONS: Preliminary analyses suggest Move IQ and SmartTrack algorithms have low overall performance for detecting walking, biking, and running activities and duration among children. Supported by: Research reported in this abstract was supported in part by the NIDDK of the National Institutes of Health under Award Numbers R01DK129215 (Weaver) and F31DK136205 (White). Co-author Finnegan was supported by the NIGMS Award Numbers T32GM081740 and T32GM145226. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health. James White was also supported in part by a SPARC Graduate Research Grant from the Office of the Vice President for Research at the University of South Carolina.

Authors

Institutions

Publication Details

Journal
Medicine & Science in Sports & Exercise
Published
2025-09-16
DOI
https://doi.org/10.1249/01.mss.0001159100.20920.81
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation Of Garmin And Fitbit Algorithms To Automatically Detect Children's Semi-structured Activity Type And Duration

J. W. White, R. Glenn Weaver, Elizabeth L. Adams, Hannah Parker et al.
Medicine & Science in Sports & Exercise
Non-Invasive Vital Sign Monitoring
article

Evaluation Of Garmin And Fitbit Algorithms To Automatically Detect Children's Semi-structured Activity Type And Duration

J. W. White, R. Glenn Weaver, Elizabeth L. Adams, Hannah Parker, Bridget Armstrong, Olivia Finnegan, Michael W. Beets, Sarah Burkart, Rahul Ghosal, Keagan Kiely
article en

Abstract

Consumer wearables with automatic activity detection algorithms have the potential to improve the assessment of children’s physical activity energy expenditure. PURPOSE: This study will evaluate the ability of Garmin Move IQ and Fitbit SmartTrack automatic activity detection algorithms to detect children’s activity type and duration compared to direct observation (DO). METHODS: Children (n = 17, 11.0 ± 1.6 years, 58.8% female) completed a ~ 60-minute, semi-structured activity protocol while wearing a Garmin Vivoactive 4S and a Fitbit Sense concurrently on their nondominant wrist. The watches were counterbalanced with each protocol, and children’s activities were measured via DO. The protocol was counterbalanced and consisted of 3 activities (walking, running [run 10 meters following the sound of an audio recording], and outdoor biking), each separated by seated rest and lasting ≥10 minutes. Activity type and duration data from Garmin and Fitbit were exported via Fitabase and translated into 1-second epochs. Epoch-by-epoch (i.e., accuracy) and measurement agreement (i.e., absolute error) analyses were conducted to evaluate the performance of Garmin Move IQ and Fitbit SmartTrack for detecting children’s activity type and duration compared to DO. RESULTS: Garmin Move IQ correctly predicted biking 71.9% (95%CI = 54.9%, 88.8%), running 5.8% (95%CI = -5.6%, 17.2%), and walking 47.6% (95%CI = 25.6%, 69.5%) of the time, while Fitbit SmartTrack correctly predicted biking 63.9% (95%CI = 43.5%, 84.3%), running 82.1% (95%CI = 67.3%, 97.0%), and walking 49.1% (95%CI = 28.9%, 69.4%) of the time. For duration, Fitbit SmartTrack produced lower mean absolute errors (biking = 3.2 ± 4.6 minutes, running = 3.7 ± 7.8, walking = 10.5 ± 13.1) than Garmin Move IQ (biking = 5.3 ± 4.6 minutes, running = 9.5 ± 2.4, walking = 16.6 ± 10.3). CONCLUSIONS: Preliminary analyses suggest Move IQ and SmartTrack algorithms have low overall performance for detecting walking, biking, and running activities and duration among children. Supported by: Research reported in this abstract was supported in part by the NIDDK of the National Institutes of Health under Award Numbers R01DK129215 (Weaver) and F31DK136205 (White). Co-author Finnegan was supported by the NIGMS Award Numbers T32GM081740 and T32GM145226. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health. James White was also supported in part by a SPARC Graduate Research Grant from the Office of the Vice President for Research at the University of South Carolina.

Medicine & Science in Sports & ExerciseVol. 57(10S)
University of South Carolina (US)
Openalex Percentile: Top 76%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.