Transient voltage stability of power systems with virtual synchronous generators or grid-following converters: analysis and enhanced control

• The active and reactive power demand characteristics of induction motors are derived theoretically. • The influence of virtual synchronous generator (VSG)/grid-following (GFL) converters on voltage stability is analyzed. • The interaction between the active and reactive power of VSG is considered and an improved VSG control is proposed. • The coordination of active and reactive power of GFL is considered and an improved GFL control is proposed. With the global energy transition, power systems are replacing synchronous generators (SGs) with voltage source converters (VSCs), which has significant implications for transient voltage stability. Analyzing VSC’s effect and leveraging its flexibility to improve stability are key challenges. Therefore, this study selects virtual synchronous generator (VSG) control and constant-power grid-following (GFL) control as representative strategies for the two dominant VSC control (grid-forming (GFM) and GFL). Then, this study theoretically derives the active and reactive power demand characteristics of induction motors. Building on these characteristics, along with the power characteristics of different power sources, the influence mechanisms of VSG and GFL on the transient voltage stability are analyzed. Distinct from existing methods, this work provides a comprehensive explanation of how induction motor power dynamics shape transient voltage behavior. The results showed that the integration of VSG and GFL degrades the transient voltage stability, with GFL exhibiting a more pronounced adverse effect. To mitigate these issues, the interaction between the active and reactive power of VSG is considered and an improved VSG control strategy is proposed to enhance the transient voltage stability. In addition, an adaptive coordinated control strategy for active and reactive power of GFL is introduced. Finally, the validity of the mechanism analysis and the effectiveness of the proposed control strategies are verified on a simplified system of a real large-scale power grid using the PSCAD platform.

Authors

Institutions

Publication Details

Journal
International Journal of Electrical Power & Energy Systems
Published
2025-09-16
DOI
https://doi.org/10.1016/j.ijepes.2025.111122
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transient voltage stability of power systems with virtual synchronous generators or grid-following converters: analysis and enhanced control

Lin Guan, Zhiying Chen
International Journal of Electrical Power & Energy Systems
Microgrid Control and Optimization
article

Transient voltage stability of power systems with virtual synchronous generators or grid-following converters: analysis and enhanced control

Lin Guan, Zhiying Chen
article en

Abstract

• The active and reactive power demand characteristics of induction motors are derived theoretically. • The influence of virtual synchronous generator (VSG)/grid-following (GFL) converters on voltage stability is analyzed. • The interaction between the active and reactive power of VSG is considered and an improved VSG control is proposed. • The coordination of active and reactive power of GFL is considered and an improved GFL control is proposed. With the global energy transition, power systems are replacing synchronous generators (SGs) with voltage source converters (VSCs), which has significant implications for transient voltage stability. Analyzing VSC’s effect and leveraging its flexibility to improve stability are key challenges. Therefore, this study selects virtual synchronous generator (VSG) control and constant-power grid-following (GFL) control as representative strategies for the two dominant VSC control (grid-forming (GFM) and GFL). Then, this study theoretically derives the active and reactive power demand characteristics of induction motors. Building on these characteristics, along with the power characteristics of different power sources, the influence mechanisms of VSG and GFL on the transient voltage stability are analyzed. Distinct from existing methods, this work provides a comprehensive explanation of how induction motor power dynamics shape transient voltage behavior. The results showed that the integration of VSG and GFL degrades the transient voltage stability, with GFL exhibiting a more pronounced adverse effect. To mitigate these issues, the interaction between the active and reactive power of VSG is considered and an improved VSG control strategy is proposed to enhance the transient voltage stability. In addition, an adaptive coordinated control strategy for active and reactive power of GFL is introduced. Finally, the validity of the mechanism analysis and the effectiveness of the proposed control strategies are verified on a simplified system of a real large-scale power grid using the PSCAD platform.

International Journal of Electrical Power & Energy SystemsVol. 172
South China University of Technology (CN)
Openalex Percentile: Top 69%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.