Electric charge neutralization of granular materials using an air-assisted ionizer under different operational conditions

An operation of electric charge neutralization is often integrated in complex electrostatic separation processes targeted at the selective sorting of the constituents of granular mixtures in a wide range of industrial applications. The aim of the present work is to prove the possibility of increasing the charge elimination efficiency of a commercial air-assisted neutralizer, under various dynamic conditions simulating realistic industrial scenarios. Three experimental setups were tested. In the first one, particles were charged by triboelectric effect and then transported by a grounded metallic conveyor belt before being subjected to ionic bombardment from the commercial neutralizer. The second configuration employed a custom-designed rotating-roll corona-electrostatic separator. Particles were charged by corona discharge and then transported on the rotating roll electrode before being neutralized by an air-assisted ionizer installed opposite the roll electrode. In the third experimental configuration, the neutralization system was installed downstream from the particle detachment step of the second configuration. After being dislodged from the grounded rotating drum by a mechanical brush, the charged insulating particles fell freely under gravity through the ionization zone. This zone comprised the commercial ionizing neutralizer positioned opposite a grounded rectangular metal plate. The factors investigated were the applied voltage ( U n ) and the distance ( d n ) between the neutralizing electrode and the grounded (belt, roll, the plate) electrode, as well as the air velocity ( v ). The findings highlight the substantial role of airflow in enhancing ion dispersion and promoting charge neutralization, particularly through its interaction with the electric field geometry and particle dynamics. For instance, residual charge-to-mass ratio dropped to as low as 1–2 nC/g in the first configuration at air velocity of 2 m/s. This study clearly demonstrates the critical importance of finely tuning geometry, electrical field strength, and air dynamics to optimize electrostatic neutralization. These findings provide valuable guidelines for designing more efficient electrostatic separation systems, particularly for industrial recycling processes involving insulating materials. Aim: increasing the efficiency of a commercial air-assisted charge neutralizer. Three electrode configurations used for simulating realistic industrial scenarios. Factors studied: applied voltage, electrode to ground distance, air velocity. Airflow enhances ion dispersion and promotes charge neutralization. Process optimization by tuning electrode geometry, electrical field, air flow.

Authors

Institutions

Publication Details

Journal
Journal of Electrostatics
Published
2025-09-16
DOI
https://doi.org/10.1016/j.elstat.2025.104168
Primary Topic
Mineral Processing and Grinding
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electric charge neutralization of granular materials using an air-assisted ionizer under different operational conditions

Thami Zeghloul, Lucian Dăscălescu, Khaled Daioui
Journal of Electrostatics
Mineral Processing and Grinding
article

Electric charge neutralization of granular materials using an air-assisted ionizer under different operational conditions

Thami Zeghloul, Lucian Dăscălescu, Khaled Daioui
article en

Abstract

An operation of electric charge neutralization is often integrated in complex electrostatic separation processes targeted at the selective sorting of the constituents of granular mixtures in a wide range of industrial applications. The aim of the present work is to prove the possibility of increasing the charge elimination efficiency of a commercial air-assisted neutralizer, under various dynamic conditions simulating realistic industrial scenarios. Three experimental setups were tested. In the first one, particles were charged by triboelectric effect and then transported by a grounded metallic conveyor belt before being subjected to ionic bombardment from the commercial neutralizer. The second configuration employed a custom-designed rotating-roll corona-electrostatic separator. Particles were charged by corona discharge and then transported on the rotating roll electrode before being neutralized by an air-assisted ionizer installed opposite the roll electrode. In the third experimental configuration, the neutralization system was installed downstream from the particle detachment step of the second configuration. After being dislodged from the grounded rotating drum by a mechanical brush, the charged insulating particles fell freely under gravity through the ionization zone. This zone comprised the commercial ionizing neutralizer positioned opposite a grounded rectangular metal plate. The factors investigated were the applied voltage ( U n ) and the distance ( d n ) between the neutralizing electrode and the grounded (belt, roll, the plate) electrode, as well as the air velocity ( v ). The findings highlight the substantial role of airflow in enhancing ion dispersion and promoting charge neutralization, particularly through its interaction with the electric field geometry and particle dynamics. For instance, residual charge-to-mass ratio dropped to as low as 1–2 nC/g in the first configuration at air velocity of 2 m/s. This study clearly demonstrates the critical importance of finely tuning geometry, electrical field strength, and air dynamics to optimize electrostatic neutralization. These findings provide valuable guidelines for designing more efficient electrostatic separation systems, particularly for industrial recycling processes involving insulating materials. Aim: increasing the efficiency of a commercial air-assisted charge neutralizer. Three electrode configurations used for simulating realistic industrial scenarios. Factors studied: applied voltage, electrode to ground distance, air velocity. Airflow enhances ion dispersion and promotes charge neutralization. Process optimization by tuning electrode geometry, electrical field, air flow.

Journal of ElectrostaticsVol. 138
Centre National de la Recherche Scientifique (FR), Institut Pprime (FR)
Openalex Percentile: Top 74%
Mineral Processing and Grinding
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.