AGREEMENT OF STEP-BASED METRICS BETWEEN ACTIGRAPH AND ACTIVPAL ACCELEROMETERS IN ADULTS 18 - 65

Step counting is a simple and widely available method of physical activity (PA) assessment. The 2018 Physical Activity Guidelines Advisory Committee concluded that more research examining stepping intensity, measured as cadence (steps/minute) is needed, including studies examining agreement between different measurement devices. PURPOSE: To compare steps and step cadence variables measured from two research-grade accelerometers: The ActiGraph (AG) and ActivPAL (AP) in a sample of adults. METHODS: Thirty women (n = 18) and men (n = 12) aged 18 – 65 years (29 ± 14 years; BMI = 24 ± 4) underwent 7 days of PA assessment while wearing an AG and AP. The AG was worn on the right hip and the AP was worn on the right thigh. Subjects completed a sleep log to document in-bed and out-of-bed times. Paired sample t-tests, mean differences, and mean absolute percentage error (MAPE) values were calculated for step-based metrics. RESULTS: Step counts per day were lower with AG (9832 ± 3302) compared to AP (10680 ± 3173, P < 0.001), with a mean difference of 848 and MAPE of 9.9%. Mean minutes of 0 cadence were also lower with AG (511 ± 79) compared to AP (627 ± 74, P < 0.001), with a mean difference of 116.3 and MAPE of 19.6%. Mean peak 1-minute cadence (128 ± 18 and 127 ± 12 for AG and AP, respectively) and mean peak 30-minute cadence (106 ± 23 and 109 ± 14) did not differ between devices. Mean differences were 1.0 and 2.8 and MAPE was 4.2% and 7.7% respectively. Mean minutes of cadence between 1 – 19, 20 – 39, 40 – 59, 60 – 79, 80 – 99, and 100 – 119 were significantly different between devices (P < 0.001), with MAPE ranging between 17.7% and 23.4%. Mean minutes of cadence >120 did not differ between devices (14 ± 19 and 15 ± 20 for AG and AP respectively). CONCLUSION: Compared to the AP, which is worn continuously for 24 hours straight, the AG underestimated daily step counts and at cadence rates >19 and at 0. Peak cadence rates for 1 or 30 minutes and cadence >120 did not differ between devices. Reasons for discrepancies across the different metrics are unclear, however discrepancies at low or no cadence likely are due to differences in how sleep and wake time are quantified between devices. Supported by: James Madison University College of Health and Behavioral Studies Research Grant Award

Authors

Institutions

Publication Details

Journal
Medicine & Science in Sports & Exercise
Published
2025-09-16
DOI
https://doi.org/10.1249/01.mss.0001160168.74999.d0
Primary Topic
Ergonomics and Musculoskeletal Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

AGREEMENT OF STEP-BASED METRICS BETWEEN ACTIGRAPH AND ACTIVPAL ACCELEROMETERS IN ADULTS 18 - 65

Trent A. Hargens, Emma Morrow
Medicine & Science in Sports & Exercise
Ergonomics and Musculoskeletal Disorders
article

AGREEMENT OF STEP-BASED METRICS BETWEEN ACTIGRAPH AND ACTIVPAL ACCELEROMETERS IN ADULTS 18 - 65

Trent A. Hargens, Emma Morrow
article en

Abstract

Step counting is a simple and widely available method of physical activity (PA) assessment. The 2018 Physical Activity Guidelines Advisory Committee concluded that more research examining stepping intensity, measured as cadence (steps/minute) is needed, including studies examining agreement between different measurement devices. PURPOSE: To compare steps and step cadence variables measured from two research-grade accelerometers: The ActiGraph (AG) and ActivPAL (AP) in a sample of adults. METHODS: Thirty women (n = 18) and men (n = 12) aged 18 – 65 years (29 ± 14 years; BMI = 24 ± 4) underwent 7 days of PA assessment while wearing an AG and AP. The AG was worn on the right hip and the AP was worn on the right thigh. Subjects completed a sleep log to document in-bed and out-of-bed times. Paired sample t-tests, mean differences, and mean absolute percentage error (MAPE) values were calculated for step-based metrics. RESULTS: Step counts per day were lower with AG (9832 ± 3302) compared to AP (10680 ± 3173, P < 0.001), with a mean difference of 848 and MAPE of 9.9%. Mean minutes of 0 cadence were also lower with AG (511 ± 79) compared to AP (627 ± 74, P < 0.001), with a mean difference of 116.3 and MAPE of 19.6%. Mean peak 1-minute cadence (128 ± 18 and 127 ± 12 for AG and AP, respectively) and mean peak 30-minute cadence (106 ± 23 and 109 ± 14) did not differ between devices. Mean differences were 1.0 and 2.8 and MAPE was 4.2% and 7.7% respectively. Mean minutes of cadence between 1 – 19, 20 – 39, 40 – 59, 60 – 79, 80 – 99, and 100 – 119 were significantly different between devices (P < 0.001), with MAPE ranging between 17.7% and 23.4%. Mean minutes of cadence >120 did not differ between devices (14 ± 19 and 15 ± 20 for AG and AP respectively). CONCLUSION: Compared to the AP, which is worn continuously for 24 hours straight, the AG underestimated daily step counts and at cadence rates >19 and at 0. Peak cadence rates for 1 or 30 minutes and cadence >120 did not differ between devices. Reasons for discrepancies across the different metrics are unclear, however discrepancies at low or no cadence likely are due to differences in how sleep and wake time are quantified between devices. Supported by: James Madison University College of Health and Behavioral Studies Research Grant Award

Medicine & Science in Sports & ExerciseVol. 57(10S)
James Madison University (US)
Openalex Percentile: Top 71%
Ergonomics and Musculoskeletal Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.