Limit Of Agreement Analysis Of Seated Single-arm Shot-put Test Assessing Upper-body Physical Function In Athlete

PURPOSE: There is a significant body of work on shot-put field tests that target the upper extremities. The Seated Single-Arm Shot-Put Test (SSASPT) has been reported to be related to isokinetic strength; however, there is limited information about its relationship to isotonic muscle performance. Compared to our previous work in isokinetics, the advantage of isotonics is that the resistance pattern is more similar to the SSASPT. Unlike isokinetic testing, isotonic muscle performance involves acceleration and inertia, allowing for the computation of muscle power. METHODS: Twenty-six male and female athletes (mean age: 21 ± 2 years, height: 173 ± 11 cm, weight: 78 ± 16 kg, Tegner Activity Scale: 9 ± 1 arb., bone-free lean mass: 54 ± 12 kg, fat mass: 20 ± 9 kg, percent body fat: 27 ± 8%) volunteered to participate in this study. Participants underwent SSASPT and isotonic dynamometry testing in a randomized order. The isotonic testing included four concentric repetitions at resistances corresponding to 1 kg, 2 kg, and 3 kg medicine ball masses. Participants' dominant and non-dominant limb order was randomized. We aimed to determine the relationships among isotonic peak power, isotonic peak torque, isotonic peak velocity, and shot-put distance and to assess the limits of agreement (sensitivity) among limb symmetry indices (LSI) computed for these variables. RESULTS: There was a moderate correlation between SSASPT distances and isotonic peak velocity (r = 0.391 to 0.504). The Bland-Altman comparison method utilizing LSI among the tests showed no significant differences in isotonic peak power (P > 0.05; 95% confidence intervals ranged from -0.098 to 0.337, mean biases from 0.055 to 0.134), isotonic peak torque (P > 0.05; 95% confidence intervals ranged from -0.279 to 0.111, mean biases from -0.085 to -0.070), and isotonic peak velocity (P > 0.05; 95% confidence intervals ranged from -0.140 to 0.083, mean biases from -0.034 to 0.008) when compared to the SSASPT distances. CONCLUSION: The results suggest that isotonic testing of the SSASPT provides more accurate insights into the field test for assessing upper body physical function in athletes. Medicine ball weights of 1 kg, 2 kg, and 3 kg are sufficient for administering this test.

Authors

Institutions

Publication Details

Journal
Medicine & Science in Sports & Exercise
Published
2025-09-16
DOI
https://doi.org/10.1249/01.mss.0001157380.93139.27
Primary Topic
Sports Performance and Training
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Limit Of Agreement Analysis Of Seated Single-arm Shot-put Test Assessing Upper-body Physical Function In Athlete

Andrew Atherton, Daniel A. Traylor, Bryan L. Riemann
Medicine & Science in Sports & Exercise
Sports Performance and Training
article

Limit Of Agreement Analysis Of Seated Single-arm Shot-put Test Assessing Upper-body Physical Function In Athlete

Andrew Atherton, Daniel A. Traylor, Bryan L. Riemann
article en

Abstract

PURPOSE: There is a significant body of work on shot-put field tests that target the upper extremities. The Seated Single-Arm Shot-Put Test (SSASPT) has been reported to be related to isokinetic strength; however, there is limited information about its relationship to isotonic muscle performance. Compared to our previous work in isokinetics, the advantage of isotonics is that the resistance pattern is more similar to the SSASPT. Unlike isokinetic testing, isotonic muscle performance involves acceleration and inertia, allowing for the computation of muscle power. METHODS: Twenty-six male and female athletes (mean age: 21 ± 2 years, height: 173 ± 11 cm, weight: 78 ± 16 kg, Tegner Activity Scale: 9 ± 1 arb., bone-free lean mass: 54 ± 12 kg, fat mass: 20 ± 9 kg, percent body fat: 27 ± 8%) volunteered to participate in this study. Participants underwent SSASPT and isotonic dynamometry testing in a randomized order. The isotonic testing included four concentric repetitions at resistances corresponding to 1 kg, 2 kg, and 3 kg medicine ball masses. Participants' dominant and non-dominant limb order was randomized. We aimed to determine the relationships among isotonic peak power, isotonic peak torque, isotonic peak velocity, and shot-put distance and to assess the limits of agreement (sensitivity) among limb symmetry indices (LSI) computed for these variables. RESULTS: There was a moderate correlation between SSASPT distances and isotonic peak velocity (r = 0.391 to 0.504). The Bland-Altman comparison method utilizing LSI among the tests showed no significant differences in isotonic peak power (P > 0.05; 95% confidence intervals ranged from -0.098 to 0.337, mean biases from 0.055 to 0.134), isotonic peak torque (P > 0.05; 95% confidence intervals ranged from -0.279 to 0.111, mean biases from -0.085 to -0.070), and isotonic peak velocity (P > 0.05; 95% confidence intervals ranged from -0.140 to 0.083, mean biases from -0.034 to 0.008) when compared to the SSASPT distances. CONCLUSION: The results suggest that isotonic testing of the SSASPT provides more accurate insights into the field test for assessing upper body physical function in athletes. Medicine ball weights of 1 kg, 2 kg, and 3 kg are sufficient for administering this test.

Medicine & Science in Sports & ExerciseVol. 57(10S)
Adrian College (US), Georgia Southern University (US)
Openalex Percentile: Top 68%
Sports Performance and Training
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.