Examining Variability In M-wave Max And Probe Positioning: A Reliability Study

Appropriate assessment of nerve function is vital to establish the outcomes of neuromuscular excitability, muscle activation, and the standardization of electromyographic data. Further, the determination of this measure has clinical relevance in the diagnosis of nerve disorders. However, factors such as probe orientation and pressure may lead to inconsistencies in the accurate assessment of nerve function. PURPOSE: The purpose of this study was to determine the interrater reliability of varying probe orientations and pressures on the maximal m-wave (M-wavemax). METHODS: Fourteen females and ten males (age: 20.9 ± 2.2 yrs) underwent electrical stimulation to the median nerve and M-wavemax was recorded in the abductor pollicis brevis. Two raters administered five conditions on separate visits to evaluate the effects of varying probe orientations and pressures on the M-wavemax response. Measures included a 1) parallel (PAR) probe nerve orientation with a pressure of 4-6 N; 2) PAR probe nerve stimulation with a pressure of 9-11 N; 3) perpendicular (PERP) nerve orientation with a pressure of 9-11 N, 4) stimulation disc electrodes in the PAR and 5) PERP direction. The intraclass correlation coefficient (ICC) was calculated for interrater reliability. The reliability of two raters was assessed using a two-way mixed model (ICC[2,1]). RESULTS: Regarding the PERP orientation, there was moderate reliability for the 9-11 N and stimulation disc electrodes (ICC(2,1) = 0.57, p = 0.003, M = 14.77, SE = 5.02; ICC(2,1) = 0.65, p = 0.211, M = 14.88, SE = 4.30; respectively). Similarly, in the PAR orientation, there was moderate reliability for the 9-11 N and stimulation patches (ICC(2,1) = 0.53, p = 0.952, M = 14.20, SE = 5.02; ICC (2,1) = 0.56, p = 0.889, M = 14.52, SE = 5.13; respectively). Lastly, in the PAR orientation, there was poor reliability for 4-6 N (ICC(2,1) = 0.33, p = 0.821, M = 13.61, SE = 5.99). CONCLUSIONS: The poor and moderate reliability indicate varying levels of consistency between the measurements acquired. This is meaningful in clinical applications because measurement reliability is crucial in the effectiveness of diagnosis and treatment. These findings suggest appropriate standardization should be emphasized to increase reliability in common peripheral nerve stimulation.

Authors

Institutions

Publication Details

Journal
Medicine & Science in Sports & Exercise
Published
2025-09-16
DOI
https://doi.org/10.1249/01.mss.0001154984.79174.56
Primary Topic
Millimeter-Wave Propagation and Modeling
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Examining Variability In M-wave Max And Probe Positioning: A Reliability Study

JoCarol E. Shields, Alejandra Barrera-Curiel, Jesus A. Hernandez-Sarabia, Jason M. DeFreitas et al.
Medicine & Science in Sports & Exercise
Millimeter-Wave Propagation and Modeling
article

Examining Variability In M-wave Max And Probe Positioning: A Reliability Study

JoCarol E. Shields, Alejandra Barrera-Curiel, Jesus A. Hernandez-Sarabia, Jason M. DeFreitas, Micheal J. Luera, Sierra M. Washington, Annalee Krahn
article en

Abstract

Appropriate assessment of nerve function is vital to establish the outcomes of neuromuscular excitability, muscle activation, and the standardization of electromyographic data. Further, the determination of this measure has clinical relevance in the diagnosis of nerve disorders. However, factors such as probe orientation and pressure may lead to inconsistencies in the accurate assessment of nerve function. PURPOSE: The purpose of this study was to determine the interrater reliability of varying probe orientations and pressures on the maximal m-wave (M-wavemax). METHODS: Fourteen females and ten males (age: 20.9 ± 2.2 yrs) underwent electrical stimulation to the median nerve and M-wavemax was recorded in the abductor pollicis brevis. Two raters administered five conditions on separate visits to evaluate the effects of varying probe orientations and pressures on the M-wavemax response. Measures included a 1) parallel (PAR) probe nerve orientation with a pressure of 4-6 N; 2) PAR probe nerve stimulation with a pressure of 9-11 N; 3) perpendicular (PERP) nerve orientation with a pressure of 9-11 N, 4) stimulation disc electrodes in the PAR and 5) PERP direction. The intraclass correlation coefficient (ICC) was calculated for interrater reliability. The reliability of two raters was assessed using a two-way mixed model (ICC[2,1]). RESULTS: Regarding the PERP orientation, there was moderate reliability for the 9-11 N and stimulation disc electrodes (ICC(2,1) = 0.57, p = 0.003, M = 14.77, SE = 5.02; ICC(2,1) = 0.65, p = 0.211, M = 14.88, SE = 4.30; respectively). Similarly, in the PAR orientation, there was moderate reliability for the 9-11 N and stimulation patches (ICC(2,1) = 0.53, p = 0.952, M = 14.20, SE = 5.02; ICC (2,1) = 0.56, p = 0.889, M = 14.52, SE = 5.13; respectively). Lastly, in the PAR orientation, there was poor reliability for 4-6 N (ICC(2,1) = 0.33, p = 0.821, M = 13.61, SE = 5.99). CONCLUSIONS: The poor and moderate reliability indicate varying levels of consistency between the measurements acquired. This is meaningful in clinical applications because measurement reliability is crucial in the effectiveness of diagnosis and treatment. These findings suggest appropriate standardization should be emphasized to increase reliability in common peripheral nerve stimulation.

Medicine & Science in Sports & ExerciseVol. 57(10S)
Syracuse University (US), Tarleton State University (US)
Openalex Percentile: Top 76%
Millimeter-Wave Propagation and Modeling
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.