Sleep Quality Assessment in Intensive Care Units: Comparing Actigraphy and the Richards Campbell Sleep Questionnaire—A Pilot Study in the Moroccan Context

Sleep in intensive care unit (ICU) patients is frequently disrupted, which may adversely affect their overall health and recovery. Despite the implementation of various strategies to promote sleep, accurately assessing its quality remains complex. This pilot study aimed to evaluate both the quality and quantity of sleep in ICU patients using actigraphy (ACT) and the Richards-Campbell Sleep Questionnaire (RCSQ) and to compare the diagnostic performance of these two tools. We conducted a prospective observational study including 228 ICU patients. Sleep was assessed using both RCSQ and ACT. Receiver Operating Characteristic (ROC) curve analysis was used to evaluate the discriminative ability of each tool (Area Under the Curve [AUC], sensitivity, specificity), with optimal cut-off points determined using Youden's Index. The Mann-Whitney U test was used to compare sleep parameters between patients classified as having good or poor sleep based on ACT measurements. The mean RCSQ score was 38.16 ± 17.09, indicating poor perceived sleep quality. Sleep onset latency (based on RCSQ) was 35.71 ± 21.44 min, with a mean of 40.32 ± 20.03 awakenings. According to ACT, sleep latency was 39.23 ± 22.09 min, and total sleep duration was 198.15 ± 128.42 min (approximately 3 h and 18 min), which is significantly below recommended levels. The average number of awakenings recorded was 24.85. In terms of diagnostic performance, the RCSQ demonstrated excellent discriminative ability (AUC = 1.00 for the total score), while ACT showed more variable results: total sleep duration had a good AUC of 0.91, while sleep latency showed a lower performance with an AUC of 0.50. The RCSQ proved to be more reliable than ACT in assessing sleep quality in ICU patients, providing consistent results across multiple parameters, including sleep depth, latency, and number of awakenings. Conversely, ACT yielded less consistent findings, particularly regarding sleep latency and nighttime interruptions. Further studies are warranted to refine objective tools for evaluating sleep in critically ill patients.

Authors

Institutions

Publication Details

Journal
Clocks & Sleep
Published
2025-09-16
DOI
https://doi.org/10.3390/clockssleep7030049
Primary Topic
Intensive Care Unit Cognitive Disorders
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sleep Quality Assessment in Intensive Care Units: Comparing Actigraphy and the Richards Campbell Sleep Questionnaire—A Pilot Study in the Moroccan Context

Youssef Bouchriti, A. Jniene, Abdelmajid Lkoul, Keltouma Oumbarek et al.
Clocks & Sleep
Intensive Care Unit Cognitive Disorders
article

Sleep Quality Assessment in Intensive Care Units: Comparing Actigraphy and the Richards Campbell Sleep Questionnaire—A Pilot Study in the Moroccan Context

Youssef Bouchriti, A. Jniene, Abdelmajid Lkoul, Keltouma Oumbarek, Tarek Dendane
article en

Abstract

Sleep in intensive care unit (ICU) patients is frequently disrupted, which may adversely affect their overall health and recovery. Despite the implementation of various strategies to promote sleep, accurately assessing its quality remains complex. This pilot study aimed to evaluate both the quality and quantity of sleep in ICU patients using actigraphy (ACT) and the Richards-Campbell Sleep Questionnaire (RCSQ) and to compare the diagnostic performance of these two tools. We conducted a prospective observational study including 228 ICU patients. Sleep was assessed using both RCSQ and ACT. Receiver Operating Characteristic (ROC) curve analysis was used to evaluate the discriminative ability of each tool (Area Under the Curve [AUC], sensitivity, specificity), with optimal cut-off points determined using Youden's Index. The Mann-Whitney U test was used to compare sleep parameters between patients classified as having good or poor sleep based on ACT measurements. The mean RCSQ score was 38.16 ± 17.09, indicating poor perceived sleep quality. Sleep onset latency (based on RCSQ) was 35.71 ± 21.44 min, with a mean of 40.32 ± 20.03 awakenings. According to ACT, sleep latency was 39.23 ± 22.09 min, and total sleep duration was 198.15 ± 128.42 min (approximately 3 h and 18 min), which is significantly below recommended levels. The average number of awakenings recorded was 24.85. In terms of diagnostic performance, the RCSQ demonstrated excellent discriminative ability (AUC = 1.00 for the total score), while ACT showed more variable results: total sleep duration had a good AUC of 0.91, while sleep latency showed a lower performance with an AUC of 0.50. The RCSQ proved to be more reliable than ACT in assessing sleep quality in ICU patients, providing consistent results across multiple parameters, including sleep depth, latency, and number of awakenings. Conversely, ACT yielded less consistent findings, particularly regarding sleep latency and nighttime interruptions. Further studies are warranted to refine objective tools for evaluating sleep in critically ill patients.

Clocks & SleepVol. 7(3)
Mohammed V University (MA), Université Ibn Zohr (MA)
Université Mohammed V de Rabat
Openalex Percentile: Top 71%
Intensive Care Unit Cognitive Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.