Thermo-Mechanical Analysis of Dowelled Timber Connections in Single Shear with the Char Layer Calculation Effect

The main goal of this work is to analyse the thermo-mechanical effect in single shear dowelled timber connections under fire conditions. This research includes the development of numerical models using the finite element method. The numerical methodology was validated using previously published experimental and numerical data. New models were developed to evaluate the temperature evolution, charring rate, and load-bearing capacity of the connections throughout exposure to fire. The calculations based on Eurocode 5 are conservative in the dimensioning of connections at room temperature but have less impact on the design of fire resistance, as they do not consider factors such as geometric parameters or passive protection influence on structural performance. Finally, based on the results obtained, two useful design equations are proposed, allowing the calculation of the load-bearing capacity of single shear timber connections, with or without protection, as a function of fire exposure.

Authors

Institutions

Publication Details

Journal
Fire
Published
2025-09-16
DOI
https://doi.org/10.3390/fire8090365
Primary Topic
Wood Treatment and Properties
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermo-Mechanical Analysis of Dowelled Timber Connections in Single Shear with the Char Layer Calculation Effect

Elza M M Fonseca, J. L. Barroso de Aguiar
Fire
Wood Treatment and Properties
article

Thermo-Mechanical Analysis of Dowelled Timber Connections in Single Shear with the Char Layer Calculation Effect

Elza M M Fonseca, J. L. Barroso de Aguiar
article en

Abstract

The main goal of this work is to analyse the thermo-mechanical effect in single shear dowelled timber connections under fire conditions. This research includes the development of numerical models using the finite element method. The numerical methodology was validated using previously published experimental and numerical data. New models were developed to evaluate the temperature evolution, charring rate, and load-bearing capacity of the connections throughout exposure to fire. The calculations based on Eurocode 5 are conservative in the dimensioning of connections at room temperature but have less impact on the design of fire resistance, as they do not consider factors such as geometric parameters or passive protection influence on structural performance. Finally, based on the results obtained, two useful design equations are proposed, allowing the calculation of the load-bearing capacity of single shear timber connections, with or without protection, as a function of fire exposure.

FireVol. 8(9)
Polytechnic Institute of Porto (PT)
Openalex Percentile: Top 73%
Wood Treatment and Properties
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.