mmPhysio: Millimetre-Wave Radar for Precise Hop Assessment

Motion tests for physiotherapy purposes are a cornerstone in a rehabilitation process. For many reasons, clinicians have been manually measuring and tracking movements so far, being subject to inaccuracies and increasing the time spent in those assessments. This paper studies the reliability of a millimetre wave (mmWave) radar to perform motion tracking for accurate hop tests. Once the variables of interest are extracted and the system set up, the results demonstrate that this system's accuracy allows its use in clinical environments, facilitating the task of tracking motion and extracting the distance covered by the subject when hopping. The radar outputs are compared against a well-known marker-based optical system, showing high agreement and validating the radar's effectiveness, with a difference of less 8 cm in the single hop test, 10 cm in the triple hop test, and 21 cm in the crossover hop test for 75% of all measurements. Hence, this approach offers a contactless, efficient, and precise alternative for physiotherapy motion assessment.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-09-15
DOI
https://doi.org/10.3390/s25185751
Primary Topic
Ultrasonics and Acoustic Wave Propagation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

mmPhysio: Millimetre-Wave Radar for Precise Hop Assessment

José A. Paredes, Felipe Parralejo, Teodoro Aguilera, Fernando J. Álvarez
Sensors
Ultrasonics and Acoustic Wave Propagation
article

mmPhysio: Millimetre-Wave Radar for Precise Hop Assessment

José A. Paredes, Felipe Parralejo, Teodoro Aguilera, Fernando J. Álvarez
article en

Abstract

Motion tests for physiotherapy purposes are a cornerstone in a rehabilitation process. For many reasons, clinicians have been manually measuring and tracking movements so far, being subject to inaccuracies and increasing the time spent in those assessments. This paper studies the reliability of a millimetre wave (mmWave) radar to perform motion tracking for accurate hop tests. Once the variables of interest are extracted and the system set up, the results demonstrate that this system's accuracy allows its use in clinical environments, facilitating the task of tracking motion and extracting the distance covered by the subject when hopping. The radar outputs are compared against a well-known marker-based optical system, showing high agreement and validating the radar's effectiveness, with a difference of less 8 cm in the single hop test, 10 cm in the triple hop test, and 21 cm in the crossover hop test for 75% of all measurements. Hence, this approach offers a contactless, efficient, and precise alternative for physiotherapy motion assessment.

SensorsVol. 25(18)
Universidad de Extremadura (ES), University of Roehampton (GB)
Openalex Percentile: Top 72%
Ultrasonics and Acoustic Wave Propagation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.