Shortening 3D T2-Weighted Breast MRI scan time using deep learning based reconstruction: A phantom and patient reader study

Motivation: 3D fast-spin-echo T2w imaging provides higher spatial resolution and wider coverage compared to 2D T2w imaging. However, 3D FSE requires longer scan time due to limited echo trains. Goal(s): To evaluate the use of pseudo-random under-sampled acquisition coupled with deep learning-based reconstruction (Sonic DL) to reduce the scan time while maintaining image quality. Approach: Quantitative analysis was performed on phantom images, and a qualitative reader study was conducted on in-vivo breast images acquired with both standard T2w imaging using Sonic DL. Results: Sonic DL with acceleration factor of 10 reduced scan time by 50% while improving signal-to-noise ratio, sharpness, and overall image quality. Impact: This work demonstrated the feasibility of using a pseudo-random under-sampled acquisition coupled with deep learning-based reconstruction (Sonic DL) to reduce 3D T2w breast MRI scan time by 50% while improving image quality.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/0097
Primary Topic
MRI in cancer diagnosis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Shortening 3D T2-Weighted Breast MRI scan time using deep learning based reconstruction: A phantom and patient reader study

Amie Y. Lee, Kevin J. Keen, Pingni Wang, Bonnie N. Joe et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
MRI in cancer diagnosis
article

Shortening 3D T2-Weighted Breast MRI scan time using deep learning based reconstruction: A phantom and patient reader study

Amie Y. Lee, Kevin J. Keen, Pingni Wang, Bonnie N. Joe, Nola Hylton, Maggie Chung, Lisa J. Wilmes, Xucheng Zhu, Shinn‐Huey S. Chou, Arnaud Guidon, C. G. Lu
article en

Abstract

Motivation: 3D fast-spin-echo T2w imaging provides higher spatial resolution and wider coverage compared to 2D T2w imaging. However, 3D FSE requires longer scan time due to limited echo trains. Goal(s): To evaluate the use of pseudo-random under-sampled acquisition coupled with deep learning-based reconstruction (Sonic DL) to reduce the scan time while maintaining image quality. Approach: Quantitative analysis was performed on phantom images, and a qualitative reader study was conducted on in-vivo breast images acquired with both standard T2w imaging using Sonic DL. Results: Sonic DL with acceleration factor of 10 reduced scan time by 50% while improving signal-to-noise ratio, sharpness, and overall image quality. Impact: This work demonstrated the feasibility of using a pseudo-random under-sampled acquisition coupled with deep learning-based reconstruction (Sonic DL) to reduce 3D T2w breast MRI scan time by 50% while improving image quality.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 63%
MRI in cancer diagnosis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.