Comparing Activation-Induced Changes in Cerebral Oxygen Metabolism Measured by Calibrated fMRI and [15O]O2-PET

Motivation: Evaluate the accuracy of calibrated functional MRI (c-fMRI) for measuring relative changes in CMRO2. Goal(s): Compare activation-induced increases in CMRO2 measured by c-fMRI to measurements from [15O]O2-PET. Approach: Data acquired on a PET/MRI scanner while participants performed finger tapping. Calibrated fMRI protocol involved hypercapnia. [15O]O2-PET images acquired at rest and during tapping. Results: Good agreement in the average CMRO2 increase in the sensorimotor cortex between the two methods, although the variability for c-fMRI was considerably greater. Impact: This study is the first direct comparison of c-fMRI to [15O]O2-PET and demonstrated the accuracy of the MRI method.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/3728
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparing Activation-Induced Changes in Cerebral Oxygen Metabolism Measured by Calibrated fMRI and [15O]O2-PET

Lucas Narciso, Michael C. Langham, Justin W. Hicks, Keith St. Lawrence et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Medical Imaging Techniques and Applications
article

Comparing Activation-Induced Changes in Cerebral Oxygen Metabolism Measured by Calibrated fMRI and [15O]O2-PET

Lucas Narciso, Michael C. Langham, Justin W. Hicks, Keith St. Lawrence, Felix Werner Wehrli, Graham Deller, Linshan Liu
article en

Abstract

Motivation: Evaluate the accuracy of calibrated functional MRI (c-fMRI) for measuring relative changes in CMRO2. Goal(s): Compare activation-induced increases in CMRO2 measured by c-fMRI to measurements from [15O]O2-PET. Approach: Data acquired on a PET/MRI scanner while participants performed finger tapping. Calibrated fMRI protocol involved hypercapnia. [15O]O2-PET images acquired at rest and during tapping. Results: Good agreement in the average CMRO2 increase in the sensorimotor cortex between the two methods, although the variability for c-fMRI was considerably greater. Impact: This study is the first direct comparison of c-fMRI to [15O]O2-PET and demonstrated the accuracy of the MRI method.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 63%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparing Activation-Induced Changes in Cerebral Oxygen Metabolism Measured by Calibrated fMRI and [15O]O2-PET — Lucas Narciso, Michael C. Langham, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2025) | TGRS Research Map | TGRS