A 9-channel 1H, 3-channel 31P RF coil for metabolic calf muscle studies at 7 T

Motivation: Combined 1H/31P MRS allows the simultaneous investigation of oxidative and glycolytic metabolic processes in exercising muscle. Insufficient proton performance of typical double-tuned radiofrequency coils can be a limitation. Goal(s): To develop a 1H/31P calf coil with excellent proton performance and minimal compromises on 31P SNR. Approach: The proposed design combines three ¹H transceive dipoles, six ¹H receive-only loops and three 31P transceive loops. Results: The developed coil showed 3.3- and 1.3-times higher 1H SNR than double- and single-tuned reference coils, improved transmit performance and enables parallel imaging. The 31P SNR was 26 % below the reference, but with a larger field of view. Impact: The developed coil will enable advanced metabolic calf muscle studies, as it combines excellent 1H performance with the possibility of acquiring high-quality 31P spectra. Combining dipoles and loops is a powerful approach for building high-density coil arrays at ultra-high field.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/5002
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A 9-channel 1H, 3-channel 31P RF coil for metabolic calf muscle studies at 7 T

Roberta Frass‐Kriegl, Martin Meyerspeer, Elmar Laistler, Veronika Cap et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

A 9-channel 1H, 3-channel 31P RF coil for metabolic calf muscle studies at 7 T

Roberta Frass‐Kriegl, Martin Meyerspeer, Elmar Laistler, Veronika Cap, Onisim Soanca, Vasco dos Santos
article en

Abstract

Motivation: Combined 1H/31P MRS allows the simultaneous investigation of oxidative and glycolytic metabolic processes in exercising muscle. Insufficient proton performance of typical double-tuned radiofrequency coils can be a limitation. Goal(s): To develop a 1H/31P calf coil with excellent proton performance and minimal compromises on 31P SNR. Approach: The proposed design combines three ¹H transceive dipoles, six ¹H receive-only loops and three 31P transceive loops. Results: The developed coil showed 3.3- and 1.3-times higher 1H SNR than double- and single-tuned reference coils, improved transmit performance and enables parallel imaging. The 31P SNR was 26 % below the reference, but with a larger field of view. Impact: The developed coil will enable advanced metabolic calf muscle studies, as it combines excellent 1H performance with the possibility of acquiring high-quality 31P spectra. Combining dipoles and loops is a powerful approach for building high-density coil arrays at ultra-high field.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 63%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.