DREAMER: Rapid, high-resolution, and simultaneous multiple-contrast magnetic resonance imaging of solid and soft tissues

Motivation: Certain clinical cases may warrant both CT and MRI. The two modalities may provide complementary information, but separate scans create a multifaceted and economic burden for the patient and imaging center. Goal(s): To develop a single scan with desirable properties from CT (bone-selective, rapid, and high-resolution) and MRI (multiple soft-tissue contrasts, no ionizing radiation). Approach: DREAMER, a dual-echo UTE sequence combined with a phase-based T2 encoding method, simultaneously encodes bone-selective, T1w, and T2w images in a single acquisition. Results: The sequence is a rapid, high-resolution, and radiation-free method to perform concurrent solid and soft tissue 3D imaging. Impact: DREAMER jointly images solid and soft tissues. The sequence may enable consolidation of CT and MRI demand at imaging centers, thereby decreasing patient examination and wait times, reducing exposure to ionizing radiation, and simplifying the clinical workflow.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/1278
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DREAMER: Rapid, high-resolution, and simultaneous multiple-contrast magnetic resonance imaging of solid and soft tissues

Chamith S. Rajapakse, Brian-Tinh Vu, Nada Kamona, Felix Werner Wehrli et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

DREAMER: Rapid, high-resolution, and simultaneous multiple-contrast magnetic resonance imaging of solid and soft tissues

Chamith S. Rajapakse, Brian-Tinh Vu, Nada Kamona, Felix Werner Wehrli, Emily Baccaglini
article en

Abstract

Motivation: Certain clinical cases may warrant both CT and MRI. The two modalities may provide complementary information, but separate scans create a multifaceted and economic burden for the patient and imaging center. Goal(s): To develop a single scan with desirable properties from CT (bone-selective, rapid, and high-resolution) and MRI (multiple soft-tissue contrasts, no ionizing radiation). Approach: DREAMER, a dual-echo UTE sequence combined with a phase-based T2 encoding method, simultaneously encodes bone-selective, T1w, and T2w images in a single acquisition. Results: The sequence is a rapid, high-resolution, and radiation-free method to perform concurrent solid and soft tissue 3D imaging. Impact: DREAMER jointly images solid and soft tissues. The sequence may enable consolidation of CT and MRI demand at imaging centers, thereby decreasing patient examination and wait times, reducing exposure to ionizing radiation, and simplifying the clinical workflow.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 63%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.