Rapid Mesoscopic Resolution DTI with High-Performance 7T

Motivation: Diffusion tensor imaging (DTI) typically requires multiple signal averaging to mitigate low signal strength, posing a challenge for rapid DTI, especially when high spatial resolutions is desired. Goal(s): This study targets a DTI resolution of 0.5 mm in-plane with the shortest possible scan time. Approach: Averaging at different resolutions on a high-performance 7T scanner and denoising were utilized for fast and high-quality DTI. Results: Mesoscopic resolution DTI with 0.5 mm resolution is possible within 10 minutes; adding denoising reduces scan time to 3 minutes. Impact: Fast and high-quality DTI with mesoscopic in-plane resolution (0.5 mm) is possible on a high-performance human 7T scanner within 3 minutes. The protocol can screen the entire brain swiftly for pathological tissues.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/4077
Primary Topic
Advanced Electron Microscopy Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid Mesoscopic Resolution DTI with High-Performance 7T

Oliver Speck, Yi‐Hang Tung, Hendrik Mattern
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced Electron Microscopy Techniques and Applications
article

Rapid Mesoscopic Resolution DTI with High-Performance 7T

Oliver Speck, Yi‐Hang Tung, Hendrik Mattern
article en

Abstract

Motivation: Diffusion tensor imaging (DTI) typically requires multiple signal averaging to mitigate low signal strength, posing a challenge for rapid DTI, especially when high spatial resolutions is desired. Goal(s): This study targets a DTI resolution of 0.5 mm in-plane with the shortest possible scan time. Approach: Averaging at different resolutions on a high-performance 7T scanner and denoising were utilized for fast and high-quality DTI. Results: Mesoscopic resolution DTI with 0.5 mm resolution is possible within 10 minutes; adding denoising reduces scan time to 3 minutes. Impact: Fast and high-quality DTI with mesoscopic in-plane resolution (0.5 mm) is possible on a high-performance human 7T scanner within 3 minutes. The protocol can screen the entire brain swiftly for pathological tissues.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 89%
Advanced Electron Microscopy Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.