Accelerated large FOV TSE body imaging at 7T using local contrast optimized AMORE

Motivation: Large field of view TSE imaging at UHF remains elusive. Goal(s): 1) Elucidate requirements needed for repetition time reduction while maintaining contrast to noise ratio (CNR). 2) Create a loss function that explicitly enforces this condition. Approach: Perform prostate and kidney TSE experiments at 7T with different repetition times and two TIAMO modes optimized for contrast and SAR calculated from a new loss function, demonstrating performance tradeoffs. Results: Reduced TR imaging using localized AMORE modes maintained prostate contrast and filled signal voids. The new contrast optimization enabled kidney acquisitions; demonstrating high scan efficiency and image quality in large FOV TSE imaging at 7T. Impact: A generalization of the AMORE method, AMORE-C, is developed that enables TSE imaging using a TR half that of standard TSE sequences. This method has minimal SAR penalties and enables large FOV imaging in the body with improved scanning efficiency.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/3446
Primary Topic
Cardiovascular Disease and Adiposity
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accelerated large FOV TSE body imaging at 7T using local contrast optimized AMORE

Tobey Haluptzok, Simon Schmidt, Gregory J. Metzger
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Cardiovascular Disease and Adiposity
article

Accelerated large FOV TSE body imaging at 7T using local contrast optimized AMORE

Tobey Haluptzok, Simon Schmidt, Gregory J. Metzger
article en

Abstract

Motivation: Large field of view TSE imaging at UHF remains elusive. Goal(s): 1) Elucidate requirements needed for repetition time reduction while maintaining contrast to noise ratio (CNR). 2) Create a loss function that explicitly enforces this condition. Approach: Perform prostate and kidney TSE experiments at 7T with different repetition times and two TIAMO modes optimized for contrast and SAR calculated from a new loss function, demonstrating performance tradeoffs. Results: Reduced TR imaging using localized AMORE modes maintained prostate contrast and filled signal voids. The new contrast optimization enabled kidney acquisitions; demonstrating high scan efficiency and image quality in large FOV TSE imaging at 7T. Impact: A generalization of the AMORE method, AMORE-C, is developed that enables TSE imaging using a TR half that of standard TSE sequences. This method has minimal SAR penalties and enables large FOV imaging in the body with improved scanning efficiency.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 62%
Cardiovascular Disease and Adiposity
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.