Scalable spokes pTx pulses for 2D turbo-spin-echo imaging at 7T

Motivation: At 7T, slice-by-slice 2D turbo-spin-echo (TSE/RARE/FSE) images are needed for clinical protocols, but show strong signal drop-outs in single transmit scans. Goal(s): Our goal is to acquire high-fidelity 2D TSE images across the whole brain using parallel transmit. Approach: PTx pulses must satisfy the Carr-Purcell-Meiboom-Gill (CPMG) conditions for good image quality. We achieve this using novel slice-selective scalable spokes pTx pulses. Results: Simulations and phantom scans show that 3-spoke scalable pulses have high flip-angle uniformity and maintain consistent phase profiles. In vivo tests show uniform images across the whole brain including in temporal lobes. VOP SAR supervision is needed for optimum TR. Impact: Scalable spokes pTx pulses produce high quality 2D-TSE images. It mitigates signal dropouts and recover diagnostic quality when single-transmit scans are inadequate. This will be valuable for patients with drug-resistant focal epilepsy to find epilepsy-causing lesions in the temporal lobes.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/3448
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Scalable spokes pTx pulses for 2D turbo-spin-echo imaging at 7T

Christopher T. Rodgers, Minghao Zhang
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Scalable spokes pTx pulses for 2D turbo-spin-echo imaging at 7T

Christopher T. Rodgers, Minghao Zhang
article en

Abstract

Motivation: At 7T, slice-by-slice 2D turbo-spin-echo (TSE/RARE/FSE) images are needed for clinical protocols, but show strong signal drop-outs in single transmit scans. Goal(s): Our goal is to acquire high-fidelity 2D TSE images across the whole brain using parallel transmit. Approach: PTx pulses must satisfy the Carr-Purcell-Meiboom-Gill (CPMG) conditions for good image quality. We achieve this using novel slice-selective scalable spokes pTx pulses. Results: Simulations and phantom scans show that 3-spoke scalable pulses have high flip-angle uniformity and maintain consistent phase profiles. In vivo tests show uniform images across the whole brain including in temporal lobes. VOP SAR supervision is needed for optimum TR. Impact: Scalable spokes pTx pulses produce high quality 2D-TSE images. It mitigates signal dropouts and recover diagnostic quality when single-transmit scans are inadequate. This will be valuable for patients with drug-resistant focal epilepsy to find epilepsy-causing lesions in the temporal lobes.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 63%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.