Motivation: Phase-contrast (PC) flow sequences are routinely used to assess hemodynamics in the heart and great vessels. At 0.55T, the use of SNR efficient acquisition strategies (spiral sampling, bSSFP) may have a role. Goal(s): We implement and compare the SNR efficiency of cartesian GRE, spiral GRE, cartesian bSSFP, and spiral bSSFP for ECG-gated PC flow measurements at 0.55T. Approach: In three healthy-volunteers, measurements of peak velocity, flow, and SNR efficiency are compared in the ascending aorta. Results: All sequences comparably measure flow rate and peak velocity. bSSFP acquisitions offer 2-fold higher SNR efficiency than GRE acquisitions and spiral sampling offers 30-40% finer temporal resolution. Impact: Flow dynamics are comparably captured by all four sequences. bSSFP PC sequences were more SNR efficient than GRE counterparts by roughly a factor of two. bSSFP Spiral acquisitions incurred unresolved flow-related artifacts.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/3511
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

SNR-efficient acquisition strategies for 2D phase contrast CMR at 0.55T

Krishna S. Nayak, Sarina Kapai, Ye Tian
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Nuclear Physics and Applications
article

SNR-efficient acquisition strategies for 2D phase contrast CMR at 0.55T

Krishna S. Nayak, Sarina Kapai, Ye Tian
article en

Abstract

Motivation: Phase-contrast (PC) flow sequences are routinely used to assess hemodynamics in the heart and great vessels. At 0.55T, the use of SNR efficient acquisition strategies (spiral sampling, bSSFP) may have a role. Goal(s): We implement and compare the SNR efficiency of cartesian GRE, spiral GRE, cartesian bSSFP, and spiral bSSFP for ECG-gated PC flow measurements at 0.55T. Approach: In three healthy-volunteers, measurements of peak velocity, flow, and SNR efficiency are compared in the ascending aorta. Results: All sequences comparably measure flow rate and peak velocity. bSSFP acquisitions offer 2-fold higher SNR efficiency than GRE acquisitions and spiral sampling offers 30-40% finer temporal resolution. Impact: Flow dynamics are comparably captured by all four sequences. bSSFP PC sequences were more SNR efficient than GRE counterparts by roughly a factor of two. bSSFP Spiral acquisitions incurred unresolved flow-related artifacts.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 68%
Nuclear Physics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.