Motivation: Cardiac magnetic resonance (CMR) parametric mapping is the gold standard for assessment of myocarditis and critical for multiple other types of acquired and congenital heart disease. Measurement drift over time can introduce bias, and parametric mapping guidelines suggest monitoring drift with a phantom; commercial phantoms are costly and have limited availability. Goal(s): To measure custom-built phantom multi-site temporal stability and measurement variation. Approach: We investigated the stability and measurement variation of manganese-chloride solution cardiac phantom T2 and T1 at multiple sites with different scanners/field-strengths. Results: We observed excellent stability for physiologically relevant phantom T2 and T1 measurements at sites for 15 months. Impact: Our preliminary results show that the designed phantom appears stable up to 15 months and allows quantification of measurement variation at different sites.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/3630
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stability and Measurement Variability of a Cardiac T1 and T2 Relaxometry Phantom

Kenneth R. Knecht, Scott R. Auerbach, Nazia Husain, Markus S. Renno et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Optical Imaging and Spectroscopy Techniques
article

Stability and Measurement Variability of a Cardiac T1 and T2 Relaxometry Phantom

Kenneth R. Knecht, Scott R. Auerbach, Nazia Husain, Markus S. Renno, Erin L. Albers, Kimberly Crum, Bruce M. Damon, Carly A. Lockard, Jonathan H. Soslow, Rebecca S. Beroukhim, Margaret M. Samyn, Kevin P. Daly, Brian Fonseca, Aspen Duffin, Ke Yan, N.M.D. Brown, Ruei-yuan Tu, Tiffanie R. Johnson
article en

Abstract

Motivation: Cardiac magnetic resonance (CMR) parametric mapping is the gold standard for assessment of myocarditis and critical for multiple other types of acquired and congenital heart disease. Measurement drift over time can introduce bias, and parametric mapping guidelines suggest monitoring drift with a phantom; commercial phantoms are costly and have limited availability. Goal(s): To measure custom-built phantom multi-site temporal stability and measurement variation. Approach: We investigated the stability and measurement variation of manganese-chloride solution cardiac phantom T2 and T1 at multiple sites with different scanners/field-strengths. Results: We observed excellent stability for physiologically relevant phantom T2 and T1 measurements at sites for 15 months. Impact: Our preliminary results show that the designed phantom appears stable up to 15 months and allows quantification of measurement variation at different sites.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 63%
Optical Imaging and Spectroscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.