Surface Tracking-assisted Real-time 4D Lung MRI

Motivation: To develop a continuous 4D lung MRI technique that captures intra- and inter-cycle variability to enable motion modeling for real-time target tracking for radiotherapy. Goal(s): To address the challenge of acquiring sufficient data for reconstruction of dynamic 3D volumes while maintaining adequate spatiotemporal resolution for radiation therapy guidance. Approach: We utilized golden angle stack-of-star acquisition, and labeled each view with continuous breathing state from a surface tracking system for sharing views with similar breathing states. Results: Continuous 4D lung MRI at 60.6ms per volume with high spatial resolution that shows movement of lung vessels. Impact: Continuous 4D lung MRI allows accurate modeling of respiration-induced internal target motion to surface motion prior to radiotherapy, and thus enables real-time target tracking during external beam radiation treatment without the need of MR linac.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/5137
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Surface Tracking-assisted Real-time 4D Lung MRI

Jiachen Zhuo, Erez Nevo, Amit Sawant, Thomas Ernst et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Atomic and Subatomic Physics Research
article

Surface Tracking-assisted Real-time 4D Lung MRI

Jiachen Zhuo, Erez Nevo, Amit Sawant, Thomas Ernst, Rao P. Gullapalli, Pan Li, Xiao Liang, Steve Roys, Hussain Soomro
article en

Abstract

Motivation: To develop a continuous 4D lung MRI technique that captures intra- and inter-cycle variability to enable motion modeling for real-time target tracking for radiotherapy. Goal(s): To address the challenge of acquiring sufficient data for reconstruction of dynamic 3D volumes while maintaining adequate spatiotemporal resolution for radiation therapy guidance. Approach: We utilized golden angle stack-of-star acquisition, and labeled each view with continuous breathing state from a surface tracking system for sharing views with similar breathing states. Results: Continuous 4D lung MRI at 60.6ms per volume with high spatial resolution that shows movement of lung vessels. Impact: Continuous 4D lung MRI allows accurate modeling of respiration-induced internal target motion to surface motion prior to radiotherapy, and thus enables real-time target tracking during external beam radiation treatment without the need of MR linac.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 81%
Atomic and Subatomic Physics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.