Quantification of T1 and T2 Metabolite Relaxation Times in Healthy Brain at 7T

Motivation: Relaxation times of brain metabolites are important for optimization of MR spectroscopy (MRS) and absolute quantification. Prior research has primarily examined relaxation times at 3T rather than 7T. Goal(s): To quantify T1 and T2 relaxation times of brain metabolites in a single scan session and same volunteers at 7T. Approach: Single-voxel MRS was acquired in the posterior cingulate cortex of healthy adults (N=6) at 7T using multi-TI and multi-TE acquisitions to quantify T1 and T2 relaxation times, respectively. Results: T1 relaxation times were reliably quantified for 20 metabolites, and T2 times for 11 metabolites, including previously unreported metabolites. Impact: T1 and T2 relaxation times of brain metabolites were measured at 7T in the same subjects and scan session. Previously unreported relaxation times were quantified for several metabolites, which are useful for optimizing acquisition parameters and quantifying absolute metabolite concentrations.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/5238
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantification of T1 and T2 Metabolite Relaxation Times in Healthy Brain at 7T

Rachel M. Goldberg, Daniel Lai, Candace C. Fleischer
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Quantification of T1 and T2 Metabolite Relaxation Times in Healthy Brain at 7T

Rachel M. Goldberg, Daniel Lai, Candace C. Fleischer
article en

Abstract

Motivation: Relaxation times of brain metabolites are important for optimization of MR spectroscopy (MRS) and absolute quantification. Prior research has primarily examined relaxation times at 3T rather than 7T. Goal(s): To quantify T1 and T2 relaxation times of brain metabolites in a single scan session and same volunteers at 7T. Approach: Single-voxel MRS was acquired in the posterior cingulate cortex of healthy adults (N=6) at 7T using multi-TI and multi-TE acquisitions to quantify T1 and T2 relaxation times, respectively. Results: T1 relaxation times were reliably quantified for 20 metabolites, and T2 times for 11 metabolites, including previously unreported metabolites. Impact: T1 and T2 relaxation times of brain metabolites were measured at 7T in the same subjects and scan session. Previously unreported relaxation times were quantified for several metabolites, which are useful for optimizing acquisition parameters and quantifying absolute metabolite concentrations.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 63%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.