Optimized contrast-to-noise ratio efficiency of Magnetization Transfer brain imaging at 0.55T

Motivation: Magnetization Transfer (MT) is an important contrast in neuroimaging that is typically limited by specific absorption rate (SAR) safety limits. Goal(s): Improve contrast-to-noise ratio (CNR) efficiency of MT ratio (MTR) mapping in the brain at 0.55T where SAR constraints are less restrictive and longer, more efficient readouts are feasible. Approach: Sequence parameters were fully constrained by hardware limits and optimized for maximum CNR efficiency of MTR between white and gray matter. A range of repetition times (TR) were explored. Results: In-vivo 3D MTR maps showed improved CNR efficiency with longer TR, with optimized sequence parameters operating at the limits of the system. Impact: Efficient acquisitions at lower field resolves the two greatest difficulties of deploying Magnetization Transfer Ratio images in the clinic, namely scan time and SAR concerns.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/1651
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimized contrast-to-noise ratio efficiency of Magnetization Transfer brain imaging at 0.55T

Shaihan Malik, Sarah McElroy, Daniel J. West, Tobias Wood et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Optimized contrast-to-noise ratio efficiency of Magnetization Transfer brain imaging at 0.55T

Shaihan Malik, Sarah McElroy, Daniel J. West, Tobias Wood, Joseph V. Hajnal, David Leitão, Raphaël Tomi‐Tricot
article en

Abstract

Motivation: Magnetization Transfer (MT) is an important contrast in neuroimaging that is typically limited by specific absorption rate (SAR) safety limits. Goal(s): Improve contrast-to-noise ratio (CNR) efficiency of MT ratio (MTR) mapping in the brain at 0.55T where SAR constraints are less restrictive and longer, more efficient readouts are feasible. Approach: Sequence parameters were fully constrained by hardware limits and optimized for maximum CNR efficiency of MTR between white and gray matter. A range of repetition times (TR) were explored. Results: In-vivo 3D MTR maps showed improved CNR efficiency with longer TR, with optimized sequence parameters operating at the limits of the system. Impact: Efficient acquisitions at lower field resolves the two greatest difficulties of deploying Magnetization Transfer Ratio images in the clinic, namely scan time and SAR concerns.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 63%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.