Ultrafast and motion-robust quantitative MRI for awake infants with brain injury using multiple overlapping-echo detachment imaging

Motivation: Quantitative MRI (qMRI) could provide microscopic insights into brain injuries in infants but is often limited by long scanning time. Goal(s): To investigate the potential of single-shot multiple overlapping-echo detachment (MOLED) imaging for motion-robust T2 and T2* mapping in awake infants. Approach: We acquired SEMOLED T2 and GREMOLED T2* maps from 8 infants (range, 10-390 days) with a total scan time of 16 seconds and compared brain T2 and T2* values across different age periods. Results: SEMOLED/GREMOLED maps demonstrated better motion tolerance than clinical MRI images. The measured T2 and T2* values show an exponentially decreasing trend with increasing age until adulthood. Impact: Due to its ultrafast quantification nature, MOLED makes it possible to quantitatively track brain development in infants affected by postnatal brain injuries, which has previously been challenging.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/2249
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrafast and motion-robust quantitative MRI for awake infants with brain injury using multiple overlapping-echo detachment imaging

Shuhui Cai, Congbo Cai, Qinqin Yang, Jianfeng Bao et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Ultrafast and motion-robust quantitative MRI for awake infants with brain injury using multiple overlapping-echo detachment imaging

Shuhui Cai, Congbo Cai, Qinqin Yang, Jianfeng Bao, Zhong Chen, Nuowei Ge
article en

Abstract

Motivation: Quantitative MRI (qMRI) could provide microscopic insights into brain injuries in infants but is often limited by long scanning time. Goal(s): To investigate the potential of single-shot multiple overlapping-echo detachment (MOLED) imaging for motion-robust T2 and T2* mapping in awake infants. Approach: We acquired SEMOLED T2 and GREMOLED T2* maps from 8 infants (range, 10-390 days) with a total scan time of 16 seconds and compared brain T2 and T2* values across different age periods. Results: SEMOLED/GREMOLED maps demonstrated better motion tolerance than clinical MRI images. The measured T2 and T2* values show an exponentially decreasing trend with increasing age until adulthood. Impact: Due to its ultrafast quantification nature, MOLED makes it possible to quantitatively track brain development in infants affected by postnatal brain injuries, which has previously been challenging.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 63%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.