A T1-independent evaluation method for steady state CEST signals

Motivation: Steady state CEST (ssCEST) is an approach to accelerate CEST experiments, which typically require long measurement times. The ssCEST-signal generally depends not only on the concentration and exchange rate of the exchanging protons but also on the T1 relaxation of the tissue. Goal(s): The aim of the work was to develop a T1-independent ssCEST method. Approach: Based on the analytical equation for spoiled gradient echo ssCEST-signals, a new T1-independent evaluation metric based on a double-angle approach was derived and tested using simulations and phantom measurements. Results: The T1-independence of the derived evaluation metric and its applicability to potatoes as plant phantoms was demonstrated. Impact: The T1-dependence of spoiled gradient echo ssCEST-signals can be eliminated and corrected by using the proposed analytical evaluation metric based on a double-angle approach.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/2463
Primary Topic
Advanced Electrical Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A T1-independent evaluation method for steady state CEST signals

Peter M. Jakob, Ljudmilla Borisjuk, Simon Mayer, Fabian Tobias Gutjahr
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced Electrical Measurement Techniques
article

A T1-independent evaluation method for steady state CEST signals

Peter M. Jakob, Ljudmilla Borisjuk, Simon Mayer, Fabian Tobias Gutjahr
article en

Abstract

Motivation: Steady state CEST (ssCEST) is an approach to accelerate CEST experiments, which typically require long measurement times. The ssCEST-signal generally depends not only on the concentration and exchange rate of the exchanging protons but also on the T1 relaxation of the tissue. Goal(s): The aim of the work was to develop a T1-independent ssCEST method. Approach: Based on the analytical equation for spoiled gradient echo ssCEST-signals, a new T1-independent evaluation metric based on a double-angle approach was derived and tested using simulations and phantom measurements. Results: The T1-independence of the derived evaluation metric and its applicability to potatoes as plant phantoms was demonstrated. Impact: The T1-dependence of spoiled gradient echo ssCEST-signals can be eliminated and corrected by using the proposed analytical evaluation metric based on a double-angle approach.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 76%
Advanced Electrical Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.