Does Phase-Based EPT with a Noise-Robust Method Provide Similar Results for GRE and bSSFP Acquisitions?

Motivation: The MagSeg phase-based electrical properties tomography (EPT) method has been shown to reduce noise in GRE but demonstrating its performance for 'gold-standard' bSSFP would broaden its applicability. Goal(s): To investigate the performance of the MagSeg method for bSSFP and GRE. Approach: MagSeg was optimised for each acquisition using a numerical phantom with SNR matched to in-vivo brain data. Tissue conductivity differences were compared for the two acquisitions. Results: MagSeg provided high-quality EPT with clear delineation between different tissue types. bSSFP had slightly lower gray-white matter EPT contrast than GRE, but higher, albeit noiser, CSF conductivities, with a mean closer to values measured ex-vivo. Impact: Using the noise-robust MagSeg method for phase-based EPT in GRE and bSSFP acquisitions provided similar high-quality conductivity maps. This performance for the 'gold-standard' bSSFP acquisition provides validation of this method and a basis for a wide range of applications.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/3436
Primary Topic
Non-Destructive Testing Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Does Phase-Based EPT with a Noise-Robust Method Provide Similar Results for GRE and bSSFP Acquisitions?

Karin Shmueli, Oriana Arsenov, Jierong Luo
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Non-Destructive Testing Techniques
article

Does Phase-Based EPT with a Noise-Robust Method Provide Similar Results for GRE and bSSFP Acquisitions?

Karin Shmueli, Oriana Arsenov, Jierong Luo
article en

Abstract

Motivation: The MagSeg phase-based electrical properties tomography (EPT) method has been shown to reduce noise in GRE but demonstrating its performance for 'gold-standard' bSSFP would broaden its applicability. Goal(s): To investigate the performance of the MagSeg method for bSSFP and GRE. Approach: MagSeg was optimised for each acquisition using a numerical phantom with SNR matched to in-vivo brain data. Tissue conductivity differences were compared for the two acquisitions. Results: MagSeg provided high-quality EPT with clear delineation between different tissue types. bSSFP had slightly lower gray-white matter EPT contrast than GRE, but higher, albeit noiser, CSF conductivities, with a mean closer to values measured ex-vivo. Impact: Using the noise-robust MagSeg method for phase-based EPT in GRE and bSSFP acquisitions provided similar high-quality conductivity maps. This performance for the 'gold-standard' bSSFP acquisition provides validation of this method and a basis for a wide range of applications.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 75%
Non-Destructive Testing Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.