Optimal k-space under sampling parttern in iterative recounstruction for radial fast spin echo MRI based on point spread function evaluation
Motivation: Radial FSE MRI is valued for motion insensitivity but requires longer acquisition times due to overlapping central k-space sampling. Optimal k-space sampling patterns for radial FSE are yet to be fully explored. Goal(s): To propose an optimal k-space sampling pattern based on PSF evaluation to improve image quality for radial FSE MRI. Approach: Simulate an radial FSE sequence, optimizing the sampling pattern by minimizing PSF differences, and evaluating image quality via NMSE against a conventional reference. Results: The proposed sampling pattern suppressed artifacts better, reducing NMSE from 0.00174 to 0.000845, with increased sampling density near the blade center and a narrower blade width. Impact: Improving acquisition speed in radial fast spin echo MRI with optimized k-space under sampling pattern and iterative reconstruction may enhance examination throughput and reduce patient burden while maintaining or enhancing image quality.
Authors
- Toru Shirai (ORCID: https://orcid.org/0000-0001-6355-9037)
- Suguru Yokosawa
- Yoshihisa Soutome
- Kuniharu Oka
Publication Details
- Journal
- Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
- Published
- 2025-09-16
- DOI
- https://doi.org/10.58530/2025/3357
- Primary Topic
- Advanced MRI Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00