LGE Imaging in Patients with Cardiac Implantable Electronic Devices at 3T: Comparison of Dixon Fat-Water Separation and Fat Suppression

Motivation: Assessment of myocardial fibrosis with late gadolinium enhancement (LGE) is crucial for patients with cardiac implantable electronic devices (CIED), but imaging quality at 3T is often limited by device-induced artifacts and poor fat suppression. Goal(s): To develop and evaluate a Dixon-based LGE sequence for scar imaging in CIED patients at 3T. Approach: We compared dual-echo Dixon with fat-suppressed LGE in a phantom and twelve patients with CIEDs at 3T. Images were rated on artifact presence and quality of fat suppression. Results: Dixon fat-water separation improved fat suppression in LGE imaging at 3T in patients with CIED. Impact: This study demonstrates that high-quality LGE images can be obtained in patients with CIED at 3T using a high-bandwidth dual-echo Dixon LGE sequence, which provides better fat suppression than conventional spectral fat saturation.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/4337
Primary Topic
Cardiovascular Function and Risk Factors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

LGE Imaging in Patients with Cardiac Implantable Electronic Devices at 3T: Comparison of Dixon Fat-Water Separation and Fat Suppression

Alexander Schulz, Reza Nezafat, Jennifer Rodriguez, Kelvin Chow et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Cardiovascular Function and Risk Factors
article

LGE Imaging in Patients with Cardiac Implantable Electronic Devices at 3T: Comparison of Dixon Fat-Water Separation and Fat Suppression

Alexander Schulz, Reza Nezafat, Jennifer Rodriguez, Kelvin Chow, Xiaoming Bi, Patrick Pierce, Fahime Ghanbari, Tess Wallace
article en

Abstract

Motivation: Assessment of myocardial fibrosis with late gadolinium enhancement (LGE) is crucial for patients with cardiac implantable electronic devices (CIED), but imaging quality at 3T is often limited by device-induced artifacts and poor fat suppression. Goal(s): To develop and evaluate a Dixon-based LGE sequence for scar imaging in CIED patients at 3T. Approach: We compared dual-echo Dixon with fat-suppressed LGE in a phantom and twelve patients with CIEDs at 3T. Images were rated on artifact presence and quality of fat suppression. Results: Dixon fat-water separation improved fat suppression in LGE imaging at 3T in patients with CIED. Impact: This study demonstrates that high-quality LGE images can be obtained in patients with CIED at 3T using a high-bandwidth dual-echo Dixon LGE sequence, which provides better fat suppression than conventional spectral fat saturation.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 62%
Cardiovascular Function and Risk Factors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.