5T cardiac cine imaging with selective PCA self-gating on normal and arrythmia subjects

Motivation: ECG has poor performance at high field and does not directly measure mechanical cardiac motion and ECG gated Cardiac MR (CMR) scans fail on arrhythmia patients. Goal(s): Our goal was to obtain the cardiac mechanical motion signal for arrhythmia cardiac cine imaging under free breathing at high field. Approach: We applied the selective PCA method developed by us to 2D cine imaging, assigning arrhythmia cardiac k-space data based on the mechanical cardiac motion. Results: The assigning of cardiac k-space data based on arrhythmia cardiac motion characteristics produced artifact-free 2D cine cardiac images, while the standard ECG-gating breath-hold technique resulted in severe artifacts. Impact: The selective PCA method yields cardiac and respiratory signals in 2D CMR imaging, acting as surrogates for ECG and belts in CMR scans. The achieved cardiac mechanical motion aids cardiac cine imaging in arrhythmic subjects.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/4320
Primary Topic
Cardiac Imaging and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

5T cardiac cine imaging with selective PCA self-gating on normal and arrythmia subjects

Wenjian Liu, Wenchao Yang, Peng Hu
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Cardiac Imaging and Diagnostics
article

5T cardiac cine imaging with selective PCA self-gating on normal and arrythmia subjects

Wenjian Liu, Wenchao Yang, Peng Hu
article en

Abstract

Motivation: ECG has poor performance at high field and does not directly measure mechanical cardiac motion and ECG gated Cardiac MR (CMR) scans fail on arrhythmia patients. Goal(s): Our goal was to obtain the cardiac mechanical motion signal for arrhythmia cardiac cine imaging under free breathing at high field. Approach: We applied the selective PCA method developed by us to 2D cine imaging, assigning arrhythmia cardiac k-space data based on the mechanical cardiac motion. Results: The assigning of cardiac k-space data based on arrhythmia cardiac motion characteristics produced artifact-free 2D cine cardiac images, while the standard ECG-gating breath-hold technique resulted in severe artifacts. Impact: The selective PCA method yields cardiac and respiratory signals in 2D CMR imaging, acting as surrogates for ECG and belts in CMR scans. The achieved cardiac mechanical motion aids cardiac cine imaging in arrhythmic subjects.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 63%
Cardiac Imaging and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.