Probing Glymphatic Exchange Between CSF and Tissue Using Long-TE Arterial Spin Labeling: Simplified Model and Shorter Scan Time

Motivation: There is currently not a clinically feasible imaging technique for the evaluation of glymphatic function. Goal(s): We proposed a new framework to measure a simple index, CSF signal fraction in ASL, which only requires 10 minutes of scan time using a single delay and two echoes. Approach: Compared to standard pCASL, the proposed sequence used enhanced background suppression, complex control and label subtraction, and a T2-preparation module with a long effective TE(eTE). Results: The parametric map had a variability of approximately 5%. An eTE of ≥480ms and a PLD of ≥2500ms are suitable for CSF fraction mapping. Impact: In this study, we developed a framework to measure CSF signal fraction in ASL MRI, which may provide a physiological index to evaluate tissue CSF dynamics and brain waste clearance system.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/0251
Primary Topic
Cerebrospinal fluid and hydrocephalus
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Probing Glymphatic Exchange Between CSF and Tissue Using Long-TE Arterial Spin Labeling: Simplified Model and Shorter Scan Time

Wen Shi, Dengrong Jiang, Jie Song, Hanzhang Lu et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Cerebrospinal fluid and hydrocephalus
article

Probing Glymphatic Exchange Between CSF and Tissue Using Long-TE Arterial Spin Labeling: Simplified Model and Shorter Scan Time

Wen Shi, Dengrong Jiang, Jie Song, Hanzhang Lu, Dinil Sasi Sankaralayam, Yulin Ge, Yifan Gou, Zihan Wang, Zhiyi Hu, Hongli Fan
article en

Abstract

Motivation: There is currently not a clinically feasible imaging technique for the evaluation of glymphatic function. Goal(s): We proposed a new framework to measure a simple index, CSF signal fraction in ASL, which only requires 10 minutes of scan time using a single delay and two echoes. Approach: Compared to standard pCASL, the proposed sequence used enhanced background suppression, complex control and label subtraction, and a T2-preparation module with a long effective TE(eTE). Results: The parametric map had a variability of approximately 5%. An eTE of ≥480ms and a PLD of ≥2500ms are suitable for CSF fraction mapping. Impact: In this study, we developed a framework to measure CSF signal fraction in ASL MRI, which may provide a physiological index to evaluate tissue CSF dynamics and brain waste clearance system.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 73%
Cerebrospinal fluid and hydrocephalus
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.