Wireless array for SNR enhancement in small animal MRI at 5T

Motivation: Clinical MRI scanners lack sufficient SNR for high-resolution small animal imaging, limiting research on diseases. Goal(s): Design a compact, wireless array to improve SNR and enable high-resolution imaging in small animal MRI at 5T. Approach: In this study, we made a wireless array and compared its imaging performance with the rat coil. Results: The wireless coil achieved high-resolution imaging of up to 0.2 mm × 0.2 mm × 0.5 mm in the 5T system. Impact: The experiment demonstrated the potential of wireless RF coils for high-resolution imaging in small animal MRI.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/3169
Primary Topic
Wireless Body Area Networks
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wireless array for SNR enhancement in small animal MRI at 5T

Chao Luo, Wei Cao, Qiaoyan Chen, Guang Yang et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Wireless Body Area Networks
article

Wireless array for SNR enhancement in small animal MRI at 5T

Chao Luo, Wei Cao, Qiaoyan Chen, Guang Yang, Du Feng, Peiyu He, Wenhao Liao, Enhua Xiao, Ye Li, Xiaoliang Zhang, Nan Li
article en

Abstract

Motivation: Clinical MRI scanners lack sufficient SNR for high-resolution small animal imaging, limiting research on diseases. Goal(s): Design a compact, wireless array to improve SNR and enable high-resolution imaging in small animal MRI at 5T. Approach: In this study, we made a wireless array and compared its imaging performance with the rat coil. Results: The wireless coil achieved high-resolution imaging of up to 0.2 mm × 0.2 mm × 0.5 mm in the 5T system. Impact: The experiment demonstrated the potential of wireless RF coils for high-resolution imaging in small animal MRI.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 76%
Wireless Body Area Networks
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.