Development of an open-source, MRI-compatible grip force sensor for dynamic muscle MRI

Motivation: Synchronising dynamic MRI acquisitions with physical force measurements enables standardised and normalised assessment of muscle activity, but requires ad hoc sensors compatible with the MR environment. Goal(s): Our goal was to develop an open-source, MRI-compatible grip force sensor for dynamic muscle MRI. Approach: Phantom and invio measurements with and without the sensor, with dynamic and anatomical scans, were performed in a 3T MRI to assess sensor compatibility, impact on field homogeneity, and potential SNR deviations. Results: The grip force sensor maintained functionality with an additional low-pass filter installed in the waveguide. The SNR decreased slightly by 3.7 % during the scans. Impact: The low-cost, open-source grip force sensor demonstrated excellent MRI compatibility and therefore appears to be suitable for use with dynamic muscle MRI methods to characterise forearm flexors, with potential applications in the study of myotonic dystrophy.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/0978
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of an open-source, MRI-compatible grip force sensor for dynamic muscle MRI

Francesco Santini, Patrick T. Panos, Marta Maggioni, Sabine Räuber
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Muscle activation and electromyography studies
article

Development of an open-source, MRI-compatible grip force sensor for dynamic muscle MRI

Francesco Santini, Patrick T. Panos, Marta Maggioni, Sabine Räuber
article en

Abstract

Motivation: Synchronising dynamic MRI acquisitions with physical force measurements enables standardised and normalised assessment of muscle activity, but requires ad hoc sensors compatible with the MR environment. Goal(s): Our goal was to develop an open-source, MRI-compatible grip force sensor for dynamic muscle MRI. Approach: Phantom and invio measurements with and without the sensor, with dynamic and anatomical scans, were performed in a 3T MRI to assess sensor compatibility, impact on field homogeneity, and potential SNR deviations. Results: The grip force sensor maintained functionality with an additional low-pass filter installed in the waveguide. The SNR decreased slightly by 3.7 % during the scans. Impact: The low-cost, open-source grip force sensor demonstrated excellent MRI compatibility and therefore appears to be suitable for use with dynamic muscle MRI methods to characterise forearm flexors, with potential applications in the study of myotonic dystrophy.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 76%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.