DIM: A Diffusion Instability Measure

Motivation: QA in diffusion MRI is challenging and rarely implemented. We provide a new QA measure that is borrowed from fMRI. Goal(s): To test a diffusion instability measure (DIM) on HARDI data from different scanners, with and without concurrent magnetic field monitoring (FM). Approach: We estimate the correlation coefficient matrix between all pairs of diffusion directions across voxels inside the phantom and compute a QA measure from the eigenvalues of the matrix. Results: DIM is sensitive to data quality affected by b-values, TE, acquisition/reconstruction types. Data acquired with FM showed a DIM value that was, on average, 10 times smaller than those without FM. Impact: We developed and tested a diffusion instability measure (DIM) that is sensitive to factors affecting image quality, such as magnetic field monitoring, f0 stabilization, TE, gradient strengths, making it a promising tool for routine diffusion MRI quality assurance.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/4049
Primary Topic
Advancements in Photolithography Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DIM: A Diffusion Instability Measure

Zoltán Nagy, Tim Schmidt
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advancements in Photolithography Techniques
article

DIM: A Diffusion Instability Measure

Zoltán Nagy, Tim Schmidt
article en

Abstract

Motivation: QA in diffusion MRI is challenging and rarely implemented. We provide a new QA measure that is borrowed from fMRI. Goal(s): To test a diffusion instability measure (DIM) on HARDI data from different scanners, with and without concurrent magnetic field monitoring (FM). Approach: We estimate the correlation coefficient matrix between all pairs of diffusion directions across voxels inside the phantom and compute a QA measure from the eigenvalues of the matrix. Results: DIM is sensitive to data quality affected by b-values, TE, acquisition/reconstruction types. Data acquired with FM showed a DIM value that was, on average, 10 times smaller than those without FM. Impact: We developed and tested a diffusion instability measure (DIM) that is sensitive to factors affecting image quality, such as magnetic field monitoring, f0 stabilization, TE, gradient strengths, making it a promising tool for routine diffusion MRI quality assurance.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 76%
Advancements in Photolithography Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.