Mitigation of T1 impact for unbiased tumor APT MRI using quasi-steady-state based apparent exchange-dependent relaxation analysis

Motivation: T1 confounds CEST measurements, leading to reduced specificity and misinterpretation of CEST MRI. Goal(s): The study aimed to investigate the feasibility of quasi-steady-state (QUASS)-based apparent exchange-dependent relaxation (AREX) analysis in correcting T1. Approach: CEST MRI experiments were conducted on a creatine phantom and brain tumor patients. Conventional CEST effect was quantified with the asymmetry analysis for the phantom or a multipool Lorentzian function for human brains from QUASS Z-spectra. The AREX metric with T1 correction was calculated from the inverse of QUASS Z-spectra. Results: Substantial T1 impact was shown on conventional CEST images, whereas the QUASS-based AREX measurements were less affected by T1. Impact: The QUASS-based AREX analysis can effectively correct the T1 confoundment in CEST measurements, facilitating unbiased tumor CEST MRI at 3 T.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/2297
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mitigation of T1 impact for unbiased tumor APT MRI using quasi-steady-state based apparent exchange-dependent relaxation analysis

Honghong Luo, Yijia Zheng, Haizhou Liu, Wei Cui et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Mitigation of T1 impact for unbiased tumor APT MRI using quasi-steady-state based apparent exchange-dependent relaxation analysis

Honghong Luo, Yijia Zheng, Haizhou Liu, Wei Cui, Dehong Luo, Yin Wu, Zhou Liu, Qian Yang
article en

Abstract

Motivation: T1 confounds CEST measurements, leading to reduced specificity and misinterpretation of CEST MRI. Goal(s): The study aimed to investigate the feasibility of quasi-steady-state (QUASS)-based apparent exchange-dependent relaxation (AREX) analysis in correcting T1. Approach: CEST MRI experiments were conducted on a creatine phantom and brain tumor patients. Conventional CEST effect was quantified with the asymmetry analysis for the phantom or a multipool Lorentzian function for human brains from QUASS Z-spectra. The AREX metric with T1 correction was calculated from the inverse of QUASS Z-spectra. Results: Substantial T1 impact was shown on conventional CEST images, whereas the QUASS-based AREX measurements were less affected by T1. Impact: The QUASS-based AREX analysis can effectively correct the T1 confoundment in CEST measurements, facilitating unbiased tumor CEST MRI at 3 T.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 63%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.