Double-step R1rho-based LOrentzian Fitting (DROF): a new CEST analysis approach and its comparison with existing methods

Motivation: At 3T MRI, reliable quantification of amide, guan, and rNOE is hindered by broad background and fitting dependency on initial values and boundary conditions. Goal(s): To propose a robust CEST analysis method for extracting 5-pool parameters at 3T and a quantitative metric to evaluate the performance of existing fitting methods. Approach: A double-step R1rho-based LOrentzian Fitting (DROF) method with random initial guesses was developed for CEST analysis. The accuracy and robustness of DROF were assessed on both simulation and in-vivo human data at 3T and compared with existing methods. Results: The new method demonstrates improved specificity and stability compared to other methods. Impact: We proposed a double-step R1rho-based LOrentzian Fitting (DROF) method for extracting 5-pool CEST parameters at 3T. DROF exhibits enhanced specificity and stability compared to other methods, suggesting its potential to promote wider CEST applications at 3T.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/1354
Primary Topic
Energy Load and Power Forecasting
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Double-step R1rho-based LOrentzian Fitting (DROF): a new CEST analysis approach and its comparison with existing methods

Bensheng Qiu, Jianpan Huang, Ziyan Wang, Jiawen Wang et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Energy Load and Power Forecasting
article

Double-step R1rho-based LOrentzian Fitting (DROF): a new CEST analysis approach and its comparison with existing methods

Bensheng Qiu, Jianpan Huang, Ziyan Wang, Jiawen Wang, Shihao Zeng, Pei Cai, Huabin Zhang
article en

Abstract

Motivation: At 3T MRI, reliable quantification of amide, guan, and rNOE is hindered by broad background and fitting dependency on initial values and boundary conditions. Goal(s): To propose a robust CEST analysis method for extracting 5-pool parameters at 3T and a quantitative metric to evaluate the performance of existing fitting methods. Approach: A double-step R1rho-based LOrentzian Fitting (DROF) method with random initial guesses was developed for CEST analysis. The accuracy and robustness of DROF were assessed on both simulation and in-vivo human data at 3T and compared with existing methods. Results: The new method demonstrates improved specificity and stability compared to other methods. Impact: We proposed a double-step R1rho-based LOrentzian Fitting (DROF) method for extracting 5-pool CEST parameters at 3T. DROF exhibits enhanced specificity and stability compared to other methods, suggesting its potential to promote wider CEST applications at 3T.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 76%
Energy Load and Power Forecasting
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.