Application of Multi-Echo SSFP Sequences Using Multiple Pathways on Short T2 Mapping

Motivation: T2 mapping is crucial for identifying abnormal tissues, while 3D clinically-approved T2 mapping sequence suffers from tradeoffs between the acquisition time and accuracy. Goal(s): To improve and validate the accuracy of short T2 mapping using the 3D multi-pathway multi-echo (MPME) sequence and its variant. Approach: The T2 calculation procedure from MPME sequence is incorporated with multi-dimensional integration (MDI) for improved accuracy. A dual-pathway dual-echo variant is developed for reducing the acquisition time. Results: Phantom results demonstrate the short T2 mapping accuracy and precision of MPME and DPDE incorporated with MDI, as compared to the reference values. Impact: Integrating MPME with MDI significantly improves its T2 mapping accuracy and precision, especially in the short T2 range, inspiring novel clinical applications that require high-speed 3D T2 mapping techniques.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/1110
Primary Topic
Algorithms and Data Compression
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of Multi-Echo SSFP Sequences Using Multiple Pathways on Short T2 Mapping

Zheng Zhong, Yongquan Ye, Fang Fěng, Paul Polak et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Algorithms and Data Compression
article

Application of Multi-Echo SSFP Sequences Using Multiple Pathways on Short T2 Mapping

Zheng Zhong, Yongquan Ye, Fang Fěng, Paul Polak, Chenyang Zhao, Junpu Hu, Bochao Li, Yujun Dong
article en

Abstract

Motivation: T2 mapping is crucial for identifying abnormal tissues, while 3D clinically-approved T2 mapping sequence suffers from tradeoffs between the acquisition time and accuracy. Goal(s): To improve and validate the accuracy of short T2 mapping using the 3D multi-pathway multi-echo (MPME) sequence and its variant. Approach: The T2 calculation procedure from MPME sequence is incorporated with multi-dimensional integration (MDI) for improved accuracy. A dual-pathway dual-echo variant is developed for reducing the acquisition time. Results: Phantom results demonstrate the short T2 mapping accuracy and precision of MPME and DPDE incorporated with MDI, as compared to the reference values. Impact: Integrating MPME with MDI significantly improves its T2 mapping accuracy and precision, especially in the short T2 range, inspiring novel clinical applications that require high-speed 3D T2 mapping techniques.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 87%
Algorithms and Data Compression
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.