Magnetization Transfer Knee Imaging at 0.05 Tesla with Extremely Low SAR

Motivation: The intrinsic low specific absorption rate (SAR) at ultra-low-field (ULF) enables the application of versatile RF pulses for magnetization transfer (MT) knee imaging. Goal(s): To explore MT knee imaging for articular cartilage evaluation at 0.05 Tesla. Approach: GRE sequences, without and with sinc-modulated RF pulse train (SPT) modules as MT preparation, were utilized for knee imaging. Results: Articular cartilage exhibits strong MT effects, with MT ratios exceeding 30% for different subjects. Both inter-examination test and multiple subject results demonstrate the robustness of ULF MT knee imaging. Moreover, the MT preparation SAR is estimated to be extremely low as 3.1mW/kg. Impact: MT knee imaging is demonstrated at 0.05 Tesla for the first time. Strong MT effects have been observed in articular cartilage with an extremely low SAR of 3.1mW/kg, rendering the potential of ULF MT knee imaging for articular cartilage evaluation.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/2012
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Magnetization Transfer Knee Imaging at 0.05 Tesla with Extremely Low SAR

Vick Lau, Liubin Wu, EX Wu, Alex S. Leong et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Medical Imaging Techniques and Applications
article

Magnetization Transfer Knee Imaging at 0.05 Tesla with Extremely Low SAR

Vick Lau, Liubin Wu, EX Wu, Alex S. Leong, Ye Ding, Jiahao Hu, Yujiao Zhao, Junhao Zhang, Shi Su, Xuehong Lin
article en

Abstract

Motivation: The intrinsic low specific absorption rate (SAR) at ultra-low-field (ULF) enables the application of versatile RF pulses for magnetization transfer (MT) knee imaging. Goal(s): To explore MT knee imaging for articular cartilage evaluation at 0.05 Tesla. Approach: GRE sequences, without and with sinc-modulated RF pulse train (SPT) modules as MT preparation, were utilized for knee imaging. Results: Articular cartilage exhibits strong MT effects, with MT ratios exceeding 30% for different subjects. Both inter-examination test and multiple subject results demonstrate the robustness of ULF MT knee imaging. Moreover, the MT preparation SAR is estimated to be extremely low as 3.1mW/kg. Impact: MT knee imaging is demonstrated at 0.05 Tesla for the first time. Strong MT effects have been observed in articular cartilage with an extremely low SAR of 3.1mW/kg, rendering the potential of ULF MT knee imaging for articular cartilage evaluation.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 63%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.