Highly-efficient simultaneous 3D radial joint T1-T2-FF mapping for isotropic resolution liver imaging at 0.55T

Motivation: Low-field MRI has potential to provide affordable diagnosis of non-alcoholic fatty liver disease. T1-T1-FF are important biomarkers as they provide information on fat, inflammation and fibrosis; yet clinical scans are lengthy and affected by respiratory motion. Goal(s): To investigate the feasibility of an efficient 3D-radial T1-T2-FF sequence for evaluating liver integrity at 0.55T. Approach: A free-running, 3D-radial, golden-angle sequence with spoiled gradient-echo readout was implemented, achieving 2.5mm isotropic resolution for joint T1-T2-FF mapping in 4min. Results: The sequence was tested on a T1-T2-FF phantom, showing good agreement with references. Promising results were obtained in healthy subjects, obtaining T1-T2-FF whole liver maps in 4min. Impact: Highly-efficient 3D radial joint T1-T2 and FF mapping of the liver using low-field MRI could provide a more affordable, accessible, and comprehensive approach for liver disease assessment.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/1096
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Highly-efficient simultaneous 3D radial joint T1-T2-FF mapping for isotropic resolution liver imaging at 0.55T

Karl Kunze, Claudia Prieto, Nicolás Garrido, René M. Botnar et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Highly-efficient simultaneous 3D radial joint T1-T2-FF mapping for isotropic resolution liver imaging at 0.55T

Karl Kunze, Claudia Prieto, Nicolás Garrido, René M. Botnar, Carlos Castillo‐Passi
article en

Abstract

Motivation: Low-field MRI has potential to provide affordable diagnosis of non-alcoholic fatty liver disease. T1-T1-FF are important biomarkers as they provide information on fat, inflammation and fibrosis; yet clinical scans are lengthy and affected by respiratory motion. Goal(s): To investigate the feasibility of an efficient 3D-radial T1-T2-FF sequence for evaluating liver integrity at 0.55T. Approach: A free-running, 3D-radial, golden-angle sequence with spoiled gradient-echo readout was implemented, achieving 2.5mm isotropic resolution for joint T1-T2-FF mapping in 4min. Results: The sequence was tested on a T1-T2-FF phantom, showing good agreement with references. Promising results were obtained in healthy subjects, obtaining T1-T2-FF whole liver maps in 4min. Impact: Highly-efficient 3D radial joint T1-T2 and FF mapping of the liver using low-field MRI could provide a more affordable, accessible, and comprehensive approach for liver disease assessment.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 63%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Highly-efficient simultaneous 3D radial joint T1-T2-FF mapping for isotropic resolution liver imaging at 0.55T — Karl Kunze, Claudia Prieto, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2025) | TGRS Research Map | TGRS