Arterial input function derived using the Xiphoid process as a reference tissue for breast DCE-MRI

Motivation: Solve the problem of accurately measuring the arterial-input-function (AIF) for breast DCE-MRI at 3T. Goal(s): To derive AIF from Xiphoid-process and compare with AIFs measured from the aorta with low and high dose (15% and 85% of standard-dose) DCE-MRI. Approach: DCE-MRI were acquired at 3T. Ktrans and ve for Xiphoid-process were measured with low-dose AIF using standard Tofts model, then used to derive AIF for high dose, and compared with high dose AIFs. Results: AIF derived using the Xiphoid-process has significantly higher peak than that measured from the aorta with a high dose, and can be used for quantitative analysis of breast DCE-MRI. Impact: The AIF derived using the Xiphoid-process as a reference tissue has significantly higher peak than that measured at descending aorta for regular-dose breast DCE-MRI, and can be used to quantitatively analyze breast DCE-MRI for diagnosis of breast cancer.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/3249
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Arterial input function derived using the Xiphoid process as a reference tissue for breast DCE-MRI

Hiroyuki Abé, Gregory S. Karczmar, Xiaobing Fan, Zhen Ren et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Arterial input function derived using the Xiphoid process as a reference tissue for breast DCE-MRI

Hiroyuki Abé, Gregory S. Karczmar, Xiaobing Fan, Zhen Ren, Olufunmilayo Olopade
article en

Abstract

Motivation: Solve the problem of accurately measuring the arterial-input-function (AIF) for breast DCE-MRI at 3T. Goal(s): To derive AIF from Xiphoid-process and compare with AIFs measured from the aorta with low and high dose (15% and 85% of standard-dose) DCE-MRI. Approach: DCE-MRI were acquired at 3T. Ktrans and ve for Xiphoid-process were measured with low-dose AIF using standard Tofts model, then used to derive AIF for high dose, and compared with high dose AIFs. Results: AIF derived using the Xiphoid-process has significantly higher peak than that measured from the aorta with a high dose, and can be used for quantitative analysis of breast DCE-MRI. Impact: The AIF derived using the Xiphoid-process as a reference tissue has significantly higher peak than that measured at descending aorta for regular-dose breast DCE-MRI, and can be used to quantitatively analyze breast DCE-MRI for diagnosis of breast cancer.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 64%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies