Techniques in Low-IF, Low Power MRI Front Ends

Motivation: Wearable MRI receive arrays are hindered by bulky cabling, and cable traps to support off-coil signal/data transfer. This impacts patient workflow and handling. Goal(s): Our goal is to identify low power techniques for balun-free receive chains that could potentially be located on the array. Approach: We have prototyped image reject low power mixers, PCB planar transformers, and low intermediate frequency active op-amp anti-aliasing filter topologies for use with a SAR ADC. Results: Fully differential op-amp antialiasing filters achieve under 30mW power, and perform >500kHz bandpass anti-aliasing at 1.25 MHz low-IF. Image rejection exceeds 40dB for only 14-18mW. Distributed on-coil signal chains are feasible. Impact: If the front end electronics can be distributed on the coil array, this opens the possibility of data transmission with a wireless interface. The receive topology could eliminate cable trap baluns, which inhibit flexibility and wearability, compromising form factor.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/3300
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Techniques in Low-IF, Low Power MRI Front Ends

John M. Pauly, Fraser Robb, Alan Michael Fontaine, Shreyas Vasanawala et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Techniques in Low-IF, Low Power MRI Front Ends

John M. Pauly, Fraser Robb, Alan Michael Fontaine, Shreyas Vasanawala, Greig Scott
article en

Abstract

Motivation: Wearable MRI receive arrays are hindered by bulky cabling, and cable traps to support off-coil signal/data transfer. This impacts patient workflow and handling. Goal(s): Our goal is to identify low power techniques for balun-free receive chains that could potentially be located on the array. Approach: We have prototyped image reject low power mixers, PCB planar transformers, and low intermediate frequency active op-amp anti-aliasing filter topologies for use with a SAR ADC. Results: Fully differential op-amp antialiasing filters achieve under 30mW power, and perform >500kHz bandpass anti-aliasing at 1.25 MHz low-IF. Image rejection exceeds 40dB for only 14-18mW. Distributed on-coil signal chains are feasible. Impact: If the front end electronics can be distributed on the coil array, this opens the possibility of data transmission with a wireless interface. The receive topology could eliminate cable trap baluns, which inhibit flexibility and wearability, compromising form factor.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 64%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.